WFL 2060 Service Tips
WFL 2060 Service Tips
--
--
Resistance
Resistance
Measurements from Control Module (2)
Measurements from Control Module (2)
70
1
1
1
1
1
1
Disconnect & measure
white 3-
pin
connector (with
blue
wires)
to measure door latch motor.
Measure between pins 1-2 (pin 1
at far left). Motor should read ~
500 - 1500
Ω
.
Pink
connector
with
pink
wires
Black
connector
with
pink
wire
Disconnect & measure
white 6-pin
connector
(with
blue
wires) to measure drum drive motor.
Motor should read (pin 1 is at far right):
•
Pins 1-2:
14 - 35
Ω
•
Pins 3-4:
1.5 - 10
Ω
•
Pins 5-6:
0.7 - 2.1
Ω
1
1
Disconnect & measure 2 connectors to measure heater. Measure
between pin 1 (far left connector in group of 7 pins) and pin 2 (2nd pin from
right) of pressure switch connector. Heater should read 23.2 - 29.4
Ω
.
WARNING
! Unplug washer before making any resistance measurements.
1st Edition/Revision 5 (1/20/04)