Operation
Operation
--
--
Sensors (2)
Sensors (2)
17
Mechanical Pressure Switch
-
(WFL 2060UC & WFR 2460 UC)
measures the water
level after the first fill. If the water level is high (like for smaller loads), the pressure
increases and the pressure switch does not provide more water.
Analog Pressure Switch -
(WFR 2460UC)
• Precise measuring of actual water level
• Accurate load detection
• Control of the pump - noise reduction
• Time reduction - no pumping when empty
BENEFITS:
BENEFITS:
Continuous adjustment of wash times
Continuous adjustment of wash times
Water and energy consumed varies according to load size
Water and energy consumed varies according to load size
1A/1B. Load & Dynamic Load Sensors
Mechanical
Pressure
Switch
Analog
Pressure
Switch
1st Edition/Revision 5 (1/20/04)
Содержание WFL 2060UC
Страница 14: ...Operation Operation Fascia Panels Fascia Panels 14 WFL 2060UC WFR 2460UC 1st Edition Revision 5 1 20 04 ...
Страница 34: ...Disassembly Disassembly Drum Drive Motor Drum Drive Motor 34 1st Edition Revision 5 1 20 04 ...
Страница 37: ...WFL 2060UC Circuit Diagram WFL 2060UC Circuit Diagram 37 1st Edition Revision 5 1 20 04 ...