VIP XD
| Installation and User Guide
EN
| 53
Bosch Security Systems | 2005-05 | V1.0
Configuration using a Web Browser
With the setting
Follows alarm 1
, the VIP XD automatically establishes a
connection to a remote station and maintains it for as long as an alarm signal is
present at alarm input 1. This option can also be used to connect two units
(transmitter and receiver) via a switch connected to the VIP XD. In this case, no
computer is needed to establish the connection.
Number of destination IP address:
Here you assign the numbering for the IP addresses to be contacted in the event
of an alarm. The unit contacts the remote locations one after the other in the
numbered sequence until a connection has been established.
Destination IP address:
For each number, enter the corresponding IP address for the desired remote
location.
Destination password:
If the remote location is password protected, enter the password here.
Auto-connect:
Select the option
On
if an active connection should be re-established
automatically to one of the previously specified IP addresses after each restart,
after a connection breakdown or network failure.
Relay
You can configure the switching behavior of the relay output. Open switch relay
(normally closed contact) or a closed switch relay (normally open contact) can
be specified.
It is also possible to specify whether the output should in a bistable or
monostable manner. In bistable operation, the activated state of the relay is
Содержание VIP XD
Страница 1: ......
Страница 12: ......
Страница 14: ...Installation and User Guide VIP XD EN 14 Product description Bosch Security Systems 2005 05 V1 0 ...
Страница 22: ...Installation and User Guide VIP XD EN 22 Installation Bosch Security Systems 2005 05 V1 0 ...
Страница 68: ...Installation and User Guide VIP XD EN 68 Operation with a terminal program Bosch Security Systems 2005 05 V1 0 ...
Страница 84: ...Bosch Security Systems 2005 05 V1 0 Installation and User Guide VIP XD EN 84 ...
Страница 85: ......