6 720 801 512 (2015/05)
Tronic 1000 T
76 | Use
4.4
Electric connection
All adjusting devices, verification and safety mechanisms were
submitted to a rigorous test in factory and are ready to work.
▶ Connect the power cable (without plug) to the building
electrical supply using a junction box. Ensure the
connection of the earth cable.
4.5
Start-up
▶ Verify that the appliance has been correctly installed and
assembled.
▶ Open the water inlet valves.
▶ Open all the hot water taps in order to ensure all the air is
out of the connections.
▶ Control the tightness of all the connections and ensure that
the appliance fills to its full capacity.
▶ Connect the appliance to the electric current.
▶ Inform the customer of any user information of the
appliance and handling.
5
Use
Fig. 8
User interface
[1] Indicator
[2] Temperature selector
5.1
User information from the technician
▶ The technician should inform the user of the functioning
and handling procedures as well as the device
maintenance.Inform the user of regular maintenance
procedures; the functioning and life span and the factors
pertinent to this. Inform the user of the need to check,
monthly the correct functioning / working order of the
security valve, opening the lever manually.
▶ During the operation of the device, water can be released
by the safety purge. Keep the purge hose outlet free from
any blockage.
▶ Inform the user that all changes or repairs are to be carried
out on the device by authorized service technicians.
▶ Hand over all the user documentation manuals and explain
their content.
DANGER:
By electrical discharge!
▶ Before working on the electrical
components, firstly cut the power,
(fuse, circuit breaker or other).
CAUTION:
Electrical protection!
▶ The appliance should dispose of an
independent connection to the DB
board (electric board), protected by a
30 mA differential circuit breaker and
earthing.
The electrical connection must be realized in
accordance with the current country laws
regarding electrical installations.
The electrical connection must be done in
accordance with the current domestic
electrical compliance installation
regulations.
2
6720643873-07.1V
1