6 720 801 512 (2015/05)
Tronic 1000 T
74 | Regulator
3
Regulator
The country’s regulations currently in force must be fulfilled for
the installation of the electric appliances
4
Installation (only for authorized
installers)
4.1
Important information
4.2
Selecting the installation location
Dispositions relative to the place of installation
•
Comply with country-specific requirements
•
Never install the appliance above a heat source.
•
Never install the appliance in rooms where the ambient
temperature can fall below 0 °C.
•
Install the appliance near the most frequently used draw-
off point to keep energy losses and waiting times to a
minimum.
•
Install the appliance in a room that permits the replacement
of the magnesium anode, and necessary maintenance
procedures.
Protection areas 1 and2
Do not install in protection areas 1 and 2.
▶ Install the appliance outside the protection areas at a
distance greater than 60 cm, of the bath.
Fig. 5
Protection areas
4.3
Water connection
It is recommended to purge the system before appliance
installation, the existence of sand can cause a reduction in flow
or even cause a total obstruction.
The installation, the connection to the
electric power, for the initialization of the
process must be exclusively be done by an
authorized technician.
CAUTION:
▶ Do not drop the appliance.
▶ Remove the appliance from the
packaging only at the place of
installation.
▶ Wherever applicable, comply with the
IEC 60364-7-701 norm on installing the
appliance and / or any electric
accessories.
▶ Chose a sufficiently robust wall to
support the appliance with the tank full,
see page 5.
CAUTION:
Damage to the heating elements!
▶ Firstly connect all the water
connections and fill the appliance.
▶ Connect the appliance to the electric
point, assuring connection to earth.
CAUTION:
▶ Make sure that the appliance is
connected to the DB board (electrical
board) with a connection to the earth
cable.
CAUTION:
Corrosion damage on the
connection cables to the appliance!
▶ Use galvanized insulators in your water
connections. These will avoid galvanic
electric currents between the hydraulic
link metals and , consequently corrosion
of these.
NOTICE:
Material damage!
▶ Install a filter at the water inlet in areas
where the water contains particles or
sediments.
225 cm
6 720 612 659-13.3TT
2
2
1
1
60 cm
60 cm