5
Bosch Security Systems 09/06 BLCC100R
Solution 16
plus
Quick Start Guide
About The Panel
Mounting The Cabinet
The cabinet should be mounted via 4 (screws/bolts)
through the 4 mounting holes in the base. Ensure that
the enclosure is mounted on a solid, flat, vertical surface
such that the base will not flex when tightened. Cabinet
dimensions are shown below.
375
25
7
90
Figure 1 : Cabinet Dimensions
Module Spaces
Each cabinet has 4 identical module spaces and 1 large
module space that is allocated for non Solution PCB boards
(eg. a securitel STU).
Each space includes 4 x 10mm stand-offs that the optional
expander PCB boards will mount using screws (screws will
be supplied with each board). The expander board will be
earthed via the screws that mount the PCB to the metal
box.
All modules will mount on these module spaces.
A list of the PCB boards is detailed below
Module
Space Occupied
Solution 16
plus
Control Panel
2 Module Spaces
CM104 Zone Expander
1 Module Space
CM110 Output Expander
1 Module Space
CM120 LAN Power Supply
1 Module Space
CM195 RF Receiver Expander
1 Module Space
Using the above table, the installer can determine how
many modules can be mounted in a single cabinet box. On
some export models, module 3 will not be available as the
transformer mounts in this location.
Figure 2: Metal Box – Module Space Allocations
Panel Led Indicators
The Solution 16
plus
PCB has two LED indicators (Dialler and
Status LED’s) which display the following information.
Condition
Meaning
Off
Offline
On
On Line (Dialling/Answered)
Flashing
Incoming Call
Table 1: Dialler LED Meanings
Condition
Meaning
Off
Error
On
Error
Flash Once Every 2 Seconds
OK
Flash Fast
AC or Battery Trouble
Table 2: Status LED Meanings
i
Note
During factory defaulting the Status and Dialler
LED indicators will be on steady for approximately
15 seconds.
Panel Address Selec t
The Solution 16
plus
pcb has three DIP switches (called Panel
Node Select) that must be set. In a multi-panel system, each
control panel (Node) must to be set to a unique address.
Panel NODE Select DIP Switch Address Settings
Panel to Address
S1
S2
S3
Panel 1
Off
Off
Off
Panel 2
On
Off
Off
Panel 3
Off
On
Off
Panel 4
On
On
Off
Panel 5
Off
Off
On
Panel 6
On
Off
On
Panel 7
Off
On
On
Panel 8
On
On
On
Table 3: Panel Node Select
i
Note
The node switch should be left at Panel 1 position
for Solution 16
plus
. OFF-OFF-OFF. On later versions
this switch may have been omitted. This is not a
fault.