Solution 16
plus
20
Bosch Security Systems 09/06 BLCC100R
Quick Start Guide
Areas > Properties >
Input Options
MENU 2-1-2
1
Non Sequential Handover (Entry Path)
Y
2
Pulse Count Handover Allowed
Y
3
Senior Watch
N
4
Reset Smoke On Arming
Y
5
Reserved
N
6
Reserved
N
7
Reserved
N
8
Reserved
N
Use Keys [
] and [
] to scroll up and down the option list. With option
selected press ON / OFF key to enable or disable option. [
] will display
to indicate option set. Press [OK] To Save when finished.
Areas > Properties >
Output Options
MENU 2-1-3
1
Arm/Disarm Speaker Beeps Via RF Keyfob
Y
2
Arm/Disarm Speaker Beeps Via Keyswitch
Y
3
Siren / Strobe When Part On Allowed
Y
4
Alarm On PIN Retry Violations
Y
5
Alarm On Exit Error
N
6
Alarm On Keyswitch Tamper ( Only If System Armed)
Y
7
Reserved
N
8
Reserved
N
Use Keys [
] and [
] to scroll up and down the option list. With option
selected press ON / OFF key to enable or disable option. [
] will display
to indicate option set. Press [OK] To Save when finished.
Areas > Properties >
Reporting Options
MENU 2-1-4
1
Report PIN Retry
Y
2
Report Exit Error
Y
3
Smart Lockout
N
4
Reserved
N
5
Cancel Reports
Y
6
Reserved
N
7
Open / Close Reports For Part On
N
8
Open / Close Reports Only After Alarm
N
Use Keys [
] and [
] to scroll up and down the option list. With option
selected press ON / OFF key to enable or disable option. [
] will display
to indicate option set. Press [OK] To Save when finished.
Areas > Properties >
Strobe Trigger
MENU 2-1-5
1
Audible Burglary Alarm
Y
2
Silent Burglary Alarm
N
3
Fire Alarm
Y
4
Arm / Disarm Flash Via RF Keyfob
N
5
Arm / Disarm Flash Via Keyswitch or PGM Input
N
6
Reserved
N
7
24-Hour Alarm
Y
8
Reserved
N
Use Keys [
] and [
] to scroll up and down the option list. With option
selected press ON / OFF key to enable or disable option. [
] will display
to indicate option set. Press [OK] To Save when finished.
Areas > Reporting >
Account Dest 1
MENU 2-2-0
0 0 0 0 0 0 0 0 0 0
Program The Area Account Number For Destination 1 Here (Enter digits
0 – 9 + [OK] To Save
Areas > Reporting >
Account Dest 2
MENU 2-2-1
0 0 0 0 0 0 0 0 0 0
Program The Area Account Number For Destination 2 Here.
Areas > Reporting >
Open / Close Route
MENU 2-2-2
0 = Report Events To Log Only
1
1 = Report Events To Destination 1 + Log
2 = Report Events To Destination 2 + Log
3 = Report Events To Destination 1 & Destination 2 + Log
4 = Report Events To Destination 2 If Destination 1 Fails +Log
Use Keys [
] and [
] keys or enter 0 - 4 + [OK] To Program Which
Destination ‘Open’ and ‘Close’ Reports Are Sent To.
Areas > Area Testing >
Area Watch
MENU 2-9-0
0 1 2
(*** System Wide Parameter ***)
WEEKS
Enter 0 – 255 + [OK] To Program The Number Of Weeks Before
Register Inactivity Event.
Areas > Area Testing >
User Test Interval
MENU 2-9-1
0 0 0
(*** System Wide Parameter ***)
DAYS
Enter 0 – 255 + [OK] To Program The Number Of Days Before A User
Test Is Requested.
Areas > Area Testing >
Service Interval
MENU 2-9-2
0 0 0
(*** System Wide Parameter ***)
WEEKS
Enter 0 – 255 + [OK] To Program The Number Of Weeks Between
Installer Service Interval.
Areas > Area Testing >
Test Options
MENU 2-9-3
1
Monitor User Test Interval
Y
2
Reserved
N
3
Reserved
N
4
Reserved
N
5
Reserved
N
6
Walk Test Reports
Y
7
Walk Test 24-Hour Zones
N
8
Walk Test Fire Zones
N
Use Keys [
] and [
] to scroll up and down the option list. With option
selected press ON / OFF key to enable or disable option. [
] will display
to indicate option set. Press [OK] To Save when finished.