Status Icons / LED’s

The following table lists the function of each of the ICON 
Symbols  and  LED  Indicators  on  the  Graphic  Keypad 
Display.

Icon

Status

Meaning

The keypad can display which areas (1 – 8) are 
turned  on  or  off  via  the  Area  Icon  Indicators. 
This  programmable option can be disabled in 
MENU 

On

The area is turned All On or Part 
On

Off

The area is turned Off

Flashing

Fast

The area has an alarm

On

System power is normal

Flashing

System power is missing

Flashing

A fire alarm is active

Off

No fire alarm

On

Fire alarm in memory (Turn the 
area All On and Off to Clear).

On

The existing service or trouble 
condition has been acknowl-
edged.

Off

No service or trouble conditions 
exist

Flashing

A service or trouble condition is 
present that has not been ac-
knowledged.

On

The area is turned Part On.

Off

The area is not turned Part On.

On

The area is turned off.

Off

The area is turned All On or Part 
On

On

The area is turned All On

Off

The area is turned Off

On

You have mail waiting to be read

Off

No Mail

On

Area is ready to turn on  
(All On / Part On)

Off

Not ready, Zone Open

Red 
LED

On

All On

Flashing

Alarm

Green 

LED

On

Area is off.

Flashing

Area not ready to turn on

Red & 

Green 

LED

Flashing

Installer programming mode is 
active.

Keypad Tones

All  keypads  emit  several  distinct  tones  and  display  text 
to alert you to system events.  The volume of the keypad 
tones can be adjusted in MENU 6-1-0.

Type

Meaning

Fire 

Alarm

Tone

When  a  fire  zone  sounds  an  alarm,  the 
keypad  will  sound  3  seconds  on  and  2 
seconds off (repeat).

Burglary  

Alarm 

Tone

When a burglary zone activates while your 
system  is  turned  on,  your  keypad  emits  a 
continuous  siren  tone.    It  sounds  for  the 
time set by your security company.

Trouble  

Tone

When  a  system  component  is  not 
functioning  properly,  your  keypad  sounds 
4 fast short beeps followed by a 5 second 
pause (repeat).

Key Press 

Tone

Pressing any key on the keypad sounds one 
short beep, indicating that the key press is 
accepted.

Entry  

Delay 

Tone

When  you  enter  the  premises  through 
a  zone  programmed  for  entry  delay,  the 
keypad sound a Hi/Low tone to remind you 
to turn off the area.  If the area is not turned 
off before the entry delay expires, an alarm 
condition will sound and a report may be 
sent to your alarm company.

Exit 

Delay 

Tone

After  you  turn  an  area  All  On,  the  keypad 
will  sound  1  short  beep  every  second.  
During the last 10 seconds fast short beeps 
will be heard.  If you don’t exit before the 
delay time expires and an exit delay door is 
faulted, an alarm occurs.

Error 

Tone

If  you  press  an  incorrect  key,  your  keypad 
will sound a 2 second tone.

Menu 
Mode

The  keypad  will  sound  a  Hi  /  Lo  tone  to 
indicate you have entered MENU Mode and 
a  Lo/Hi  tone  to  indicate  you  have  exited 
MENU mode.

Chime 

Tone

The keypad sounds fast short beeps to alert 
you when a zone programmed for chime is 
faulted or unsealled.

Содержание Solution 16plus

Страница 1: ...Solution 16plus Security System Quick Start Guide EN ...

Страница 2: ... you find any error on inconsistency please notify us accordingly Bosch Security Systems Pty Ltd reserves the right to make changes to features and specifications at any time without prior notification in the interest of ongoing product development and improvement Telepermit Note The grant of a Telepermit for a device in no way indicates Telecom acceptance of responsibility for the correct operation ...

Страница 3: ...eporting Code Reference Listing 14 Table 12 Menu Structure And Layout 17 Table 13 User Default Programming Options 18 Table 14 Zone Types 21 Table 15 Zone Defaults 22 Table 16 Output Default Table 23 Table 17 Output Polarity Types 24 Table 18 Output Event Types 24 CONTENTS Copyright Notice 2 Trademarks 2 Notice of Liability 2 Telepermit Note 2 FEATURES 4 OVERVIEW 4 ABOUT THE PANEL 5 Mounting The C...

Страница 4: ...lt In Remote Arming Overview Zones The Solution 16plus control panel provides up to 16 separate zones of protection Zone programming determines the panel s response to open short and tamper conditions on the zone loop Areas The control panel supports up to 4 separate areas You can assign all zones to a single area or you can assign each zone to a combination of different areas You can arm and disar...

Страница 5: ...le the installer can determine how many modules can be mounted in a single cabinet box On some export models module 3 will not be available as the transformer mounts in this location Figure 2 Metal Box Module Space Allocations Panel Led Indicators The Solution 16plus PCB has two LED indicators Dialler and Status LED s which display the following information Condition Meaning Off Offline On On Line Di...

Страница 6: ...y zone configurations using Normally Closed Alarm contacts and Normally Open Alarm Contacts When using Normally Open Alarm Contacts you must select Inverted Seal for each zone in MENU 3 1 8 A shorted loop is a tamper condition for all EOL zone configurations 2 ZONE 2 N O N O ZONE 1 Figure 7 N O No EOL Zone ZONE 2 ZONE 1 N O N O ALARM ALARM Figure 8 N O Single EOL Zone 6K8 EOL 3K3 EOL N O N O ALARM A...

Страница 7: ...7 Bosch Security Systems 09 06 BLCC100R Solution 16plus Quick Start Guide Figure 12 Solution 16plus Board Layout ...

Страница 8: ...N C N C N C N C ZONE 6 ZONE 8 ZONE 5 ZONE 7 N C N C N C N C LAN B LAN LAN A LAN Keypad LAN Expansion Device Horn Speaker Strobe Light NOTE For Piezo Siren Operation Short Relay Select PINS COM and GND 12VDC 7Ah Sealed Lead Acid Battery Accessories e g PIR Detectors Siren Tamper Switch Connect To Cabinet Tamper Connect To Zone Terminals NC COM RJ12 6P4C To RJ12 6P4C Telephone Lead Connect To Teleph...

Страница 9: ...one 5 and 6 sensor loop Nº Name Description 32 ZN 6 Zone 6 and 14 sensor loop input 33 ZN 7 Zone 7 and 15 sensor loop input 34 GND Common for Zone 7 and 8 sensor loop 35 ZN 8 Zone 8 and 16 sensor loop input 36 37 IN IN These terminals are used to connect the telephone line from the street 38 39 OUT OUT These terminals are used to connect the premises telephones Table 4 Terminal Block Descriptions ...

Страница 10: ...conds will cause a Panic alarm to be triggered If programmed the sirens will sound and the monitoring station will be notified for 2 sec Pressing the 4 and 6 keys together and holding them down for 2 seconds will cause a Fire alarm to be triggered If programmed the sirens will sound and the monitoring station will be notified Key Description for 2 sec Pressing the 7 and 9 keys together and holding t...

Страница 11: ...s and display text to alert you to system events The volume of the keypad tones can be adjusted in MENU 6 1 0 Type Meaning Fire Alarm Tone When a fire zone sounds an alarm the keypad will sound 3 seconds on and 2 seconds off repeat Burglary Alarm Tone When a burglary zone activates while your system is turned on your keypad emits a continuous siren tone It sounds for the time set by your security co...

Страница 12: ...ng mode a special menu called the Command Menu will appear at the top of the menu tree The Command Menu provides a list of the most common system funtions like Turn Chime Mode On Move To An Area or Turn An Area On Use the up and down arrow keys to navigate and press OK to select the command Programming Option Bit Menus Use the up and down arrow keys to scroll through the 8 different options To sele...

Страница 13: ...ow keys to change Press OK to save or MENU to exit without saving i Note Scroll through hours to change from am to pm SET DATE AND TIME i01 Jan 2005 12 00 am PRESS OK to SAVE Figure 19 Clock Programming Display Getting Started Back To Base The following steps are the mimimum requirements to get the system reporting back to base Examples assume the panel is disarmed with no alarms and starting from...

Страница 14: ...rect Link module which connected the panels serial port to the PC Once the cable is connected you will need to hold down the default switch on the panel for 5 seconds to initiate the programming session See Figure 12 for the default switch location It is also possible to initiate the programming session via MENU 5 0 5 Start Direct Link Zone Array The feature allows you to view the condition of 16 ...

Страница 15: ...dd PIN AUMI 2 0 5 Chime On Off AUMI 4 0 0 Output Status MI 1 1 3 Delete PIN UMI 2 0 6 Chime Mode UMI 4 0 1 Turn Output On Off I 1 1 4 View PIN MI 7 1 0 Set Date Time 2 1 Area Properties UMI 3 0 5 Smoke Sensor Reset 1 2 Token MI 2 1 0 Area Name UMI 3 9 0 Walk Test All Zones MI 1 2 0 Add Token I 2 1 1 General Options MI 4 9 0 External Siren Test MI 1 2 1 Delete Token I 2 1 2 Input Options MI 4 9 1 Int...

Страница 16: ... 1 2 Secondary Dest 1 I 3 1 7 Report Options MI 4 9 2 Strobe Test I 5 1 3 Primary Dest 2 I 3 1 8 Zone Options I 5 1 4 Secondary Dest 2 MI 5 1 5 Domestic Numbers 3 3 RF Zone MI 5 1 6 Call Forward On I 3 3 0 Add RF Device MI 5 1 7 Call Forward Off I 3 3 1 Delete RF Device I 3 3 2 Test RF Device 5 2 Properties I 5 2 0 Call Attempt Count 3 4 Global Input Options I 5 2 1 Dialler Options I 3 4 0 EOL Valu...

Страница 17: ...2 2 Entry Time 2 I 6 2 2 RF Device Options I 7 2 3 Part Entry Time I 6 2 3 Add RF Keypad I 7 2 4 Auto Arm Pre Alert I 6 2 4 Delete RF Keypad I 7 2 5 Output Pre Alert I 6 2 5 View RF Device ID I 7 2 6 Senior Watch Time 6 3 Serial Device 7 3 Power I 6 3 0 Device Type I 7 3 0 AC Options I 6 3 1 Baud Rate I 7 3 1 Battery Options I 6 3 2 Flow Control I 7 3 2 Fuse Options 6 5 GSM Modem 7 4 Siren I 7 4 0...

Страница 18: ...en Status MENU 1 2 2 Access RF Keyfob Add Keyfob MENU 1 3 0 Delete Keyfob MENU 1 3 1 Test Keyfob MENU 1 3 2 Access User Properties User Name MENU 1 4 0 U s e r 1 N a m e Use the left and right arrow keys to scroll cursor left and right Use Keys 0 9 or the up and down arrows to scroll characters then press OK To Save Access Global Properties Area Assignment MENU 1 4 1 1 Area 1 Y 2 Area 2 N 3 Area 3...

Страница 19: ...roup Access Prox Reader Reader Options MENU 1 6 3 1 All On Arming Allowed Y 2 Disarming Allowed Y 3 Badging Required N 4 Zero Exit Time N 5 Part On Badging Allowed N 6 Arm If Single Area User N 7 Reserved N 8 Reserved N Use Keys and to scroll up and down the option list With option selected press ON OFF key to enable or disable option will display to indicate option set Press OK To Save when finis...

Страница 20: ...a Keyswitch or PGM Input N 6 Reserved N 7 24 Hour Alarm Y 8 Reserved N Use Keys and to scroll up and down the option list With option selected press ON OFF key to enable or disable option will display to indicate option set Press OK To Save when finished Areas Reporting Account Dest 1 MENU 2 2 0 0 0 0 0 0 0 0 0 0 0 Program The Area Account Number For Destination 1 Here Enter digits 0 9 OK To Save ...

Страница 21: ...t Time Inputs Zone Properties Pulse Count Time MENU 3 1 4 1 2 0 SECONDS Enter 0 255 OK To Program The Period Of Time In Seconds That The Pulse Count Must Register Inputs Zone Properties Access Group MENU 3 1 5 0 Use Keys and keys or enter 1 8 OK To Assign The Zone To An Access Group 0 Disabled Inputs Zone Properties Report Route MENU 3 1 6 0 Report Events To Log Only 1 1 Report Events To Destinati...

Страница 22: ...nt 0 0 0 0 0 Pulse Count Time Sec s 120 120 120 120 120 Access Group 0 0 0 0 0 Report Route 2 2 2 2 2 Reporting Options Lockout Dialler Y Y Y Y Y Report Alarm Y Y Y Y Y Report Alarm Restore Y Y Y Y Y Report Trouble Y Y Y Y Y Report Trouble Restore Y Y Y Y Y Report Bypass Y Y Y Y Y Report Bypass Restore Y Y Y Y Y Delay Report N N N N N Zone Options Lockout Siren Y Y Y Y Y Silent Alarm N N N N N Inv...

Страница 23: ...r Access Group Number You Want The Output To Follow Then Press OK 0 Unrestricted all Areas Users Zones etc Output Default Table The table below list the default values for all Output parameters in the Solution 16plus Outputs 1 to 3 are High current digital outputs and Output 4 is the onboard relay output Outputs 5 to 8 are only available if the optional Output Relay Expander Boards CM110 are fitted...

Страница 24: ...9 Smoke Sensor GND A 25 Area Part 2 On A 50 Sensor Watch A Table 18 Output Event Types Outputs Properties Output Polarity MENU 4 1 3 0 0 Enter 0 14 OK To Program The Output Polarity See table below for avaiable polarity types Each Output Can Only Have One Option Programmed Option Polarity 0 Normally Open Going Low 1 Normally Open Going Low With Pre Delay 2 Normally Open Latching Low 3 Normally Ope...

Страница 25: ... Use and To Toggle Special Characters and Pause Comms Telephone Number Primary Dest 1 MENU 5 1 1 1 Digits 32 Use and Keys To Scroll Cursor Enter 0 9 For Telephone Digits Use and To Toggle Special Characters and Pause Comms Telephone Number Secondary Dest 1 MENU 5 1 2 1 Digits 32 Use and Keys To Scroll Cursor Enter 0 9 For Telephone Digits Use and To Toggle Special Characters and Pause Comms Teleph...

Страница 26: ...Portugal 12 China 3 Italy 8 Hungary 13 Hong Kong 4 Greece 9 Czech Republic 14 Malaysia 5 Cyprus 10 Poland 15 Brazil 6 Spain 11 Bulgaria Use Keys and keys or enter 0 15 OK To Set Which Country The Panel Is Being Used In Only 1 Option Can Be Programmed System Wide Parameter Comms Properties Set SMS Pasword MENU 5 2 7 p a s s w d Use keys 0 9 To Program SMS Password OK To Save Use and Keys To Scroll ...

Страница 27: ...ort To Destination 1 Only 1 Option Can Be Programmed Comms Dialler Reporting TX Format Dest 2 MENU 5 4 1 0 Disable 1 1 Contact ID 7 Domestic 2 SIA 8 Voice 13 Reserved 3 Serial STU 9 SIA 14 Reserved 4 GSM 10 Reserved 15 Reserved 5 WEB MAIL 11 Reserved 6 SMS 12 Reserved Use Keys and keys or enter 0 15 Then Press OK To Program The Transmission Format The Control Panel Will Use To Report To Destinatio...

Страница 28: ...K To Save when finished Comms Comms Test Test Route MENU 5 9 4 0 Report Events To Log Only 1 1 Report Events To Destination 1 Log 2 Report Events To Destination 2 Log 3 Report Events To Destination 1 Destination 2 Log 4 Report Events To Destination 2 If Destination 1 Fails Log Use Keys and keys or enter 0 4 OK To Enter Single Option Only System Wide Parameter Comms Comms Test Dial Number Test MENU...

Страница 29: ...Jam Detect N 6 Alarm On RF Receiver Comms Fail Y 7 Report RF Receiver Comms Fail Y 8 Reserved N Use Keys and to scroll up and down the option list With option selected press ON OFF key to enable or disable option will display to indicate option set Press OK To Save when finished Device RF Devices Supervision Time MENU 6 2 1 0 2 4 HOURS Enter the RF Supervision Time for Devices in Hours 001 255 Hou...

Страница 30: ...de Parameter SECONDS Enter 0 255 OK To Program The Entry Time In Seconds System Timers Entry Time 2 MENU 7 2 2 0 4 0 System Wide Parameter SECONDS Enter 0 255 OK To Program The Entry Time In Seconds System Timers Part Entry Time MENU 7 2 3 0 6 0 System Wide Parameter SECONDS Enter 0 255 OK To Program The Part Mode Entry Time In Seconds System Timers Auto Arm Pre Alert MENU 7 2 4 0 1 0 System Wide ...

Страница 31: ... 0 15 OK To Program Number Of Times Siren Can Sound Before Lockout 0 Unlimited System Wide Parameter System Schedules Name MENU 7 5 0 S c h e d u l e 1 N a m e Use and Keys To Scroll Cursor Left and Right Use Keys 0 9 and To Toggle Characters Enter OK To Save System Schedules Time MENU 7 5 1 Start Time Stop Time 12 00 am 12 00 am HH MM HH MM Use the and keys to move to the field then and to change...

Страница 32: ...s and keys To Program The High Low Keypad Monitor Temperature Max 50 Min 0 System Installer Options Installer Options MENU 7 7 4 1 Report Log Entry Exit Intstaller Menu N 2 Report Log Program Data Change Y 3 Arm Only Installer Pin N 4 Reserved N 5 Auto Exit Installer Menu In 2 Hours Y 6 Auto Exit Service mode In 2 Hours Y 7 Reserved N 8 Factory Defaulting Allowed Y Use Keys and to scroll up and do...

Страница 33: ...tible Keypads CP100 Graphic CP101 Graphic Prox CP110 Graphic Black CP111 Graphic Prox Black Compatible Accessories CM104 8 16 Zone Expander CM110 4 Way Relay Output Module CM120 1 Amp LAN Power Supply CM195 Multi RF Receiver Interface SW500B Solution Link RAS Software CM900 Direct Link Interface Enclosure Dimensions 375mm W 257mm H 90mm D Part Number MW100 PWA Dimensions 235mm W 40mm H 85mm D Warr...

Страница 34: ...Solution 16plus 34 Bosch Security Systems 09 06 BLCC100R Quick Start Guide NOTES ...

Страница 35: ...plus Quick Start Guide INSTALLATION DETAILS CUSTOMER NAME PHONE INSTALLED BY DATE ACCOUNT N PANEL LOCATION PANEL PHONE N CLI ENABLED N WIRED ZONES N OF USERS N RF ZONES N OF AREAS WARRANTY EXPIRES COMMON AREA USED USER TRAINING DONE PERSON TRAINED NOTES ...

Страница 36: ...Bosch Security Systems 25 Huntingwood Drive Huntingwood NSW 2128 Australia Phone 612 9672 1777 Facsimile 612 9672 1717 2006 Bosch Security Systems BLCC100R 920656 Issue FTR1 1 ...

Отзывы: