SM Series Heat Pump
SM Series Heat Pump
6 720 220 406 (2015/02)
Subject to change without prior notice
62
|
Airflow Tables
AIRFLOW TABLES
Constant Torque Motor Airflow Table
(SM0**-***-***-T*)
ECM Const Torque Motor - X13
Models
Fan
Speed
Rated
Airflow
Factory
setting
External Static Pressure (in of Water)
0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20
SM024
5
950
1154 1117 1077 1034
988
938
886
830
-
-
-
-
4
825
FL
1072 1018
966
915
866
818
772
727
-
-
-
-
3
725
976
920
867
815
766
719
674
631
-
-
-
-
2
650
PL/Fan only
906
844
785
730
678
630
585
544
-
-
-
-
1
500
829
750
676
610
551
498
451
412
-
-
-
-
SM036
5
1300
1506 1469 1430 1390 1347 1300 1249 1193 1130 1061
-
-
4
1100
FL
1425 1326 1250 1191 1143 1100 1056 1006
942
860
-
-
3
950
1354 1233 1138 1063 1002
950
901
850
791
719
-
-
2
800
PL/Fan only
1294 1157 1041
946
866
800
744
696
653
611
-
-
1
750
1213 1084
976
886
812
750
698
653
612
573
SM048
5
1800
1950 1912 1880 1852 1826 1800 1771 1737 1695 1644
-
-
4
1600
FL
1774 1738 1703 1669 1635 1600 1562 1521 1475 1423
-
-
3
1400
1565 1526 1493 1463 1432 1400 1363 1319 1265 1199
-
-
2
1300
PL/Fan only
1506 1469 1430 1390 1347 1300 1249 1193 1130 1061
-
-
1
1100
1425 1326 1250 1191 1143 1100 1056 1006
942
860
-
-
SM060
5
2200
2476 2403 2338 2283 2237 2200 2172 2153 2142 2141 2149 2166
4
2000
FL
2170 2135 2100 2066 2033 2000 1968 1937 1907 1877 1848 1819
3
1800
1942 1914 1886 1858 1829 1800 1770 1741 1710 1680 1649 1617
2
1600
PL/Fan only
1766 1729 1693 1660 1629 1600 1573 1548 1526 1505 1487 1470
1
1400
1561 1520 1483 1451 1423 1400 1381 1366 1356 1350 1349 1352
SM070
5
2500
2723 2671 2622 2578 2537 2500 2467 2437 2412 2390 2372 2358
4
2350
FL
2566 2529 2489 2446 2399 2350 2298 2242 2184 2122 2057 1990
3
2100
2256 2230 2202 2171 2137 2100 2060 2017 1971 1922 1871 1816
2
1850
PL/Fan only
2004 1975 1945 1915 1883 1850 1816 1781 1745 1708 1669 1630
1
1600
1766 1728 1693 1660 1629 1600 1573 1548 1526 1505 1486 1470
FL Full Load
PL Part Load