en | Configuring the IP AutoDome
VG4 Modular Camera System
F.01U.133.268 | 6.0 | 2010.03
User’s Manual
Bosch Security Systems, Inc.
Rule Definition
Select Input Option 8 through 12 from the left pane, then select a type:
–
None: no trigger event is selected.
–
Aux On: triggers alarms with one respective Aux On command.
–
Aux Off: triggers alarms with one respective Aux Off command.
–
Shot: triggers alarms when the camera is set to one pre-position.
–
Tracking: Alarm input option that turns the tracker on when the alarm is activated.
–
Motion Detection: triggers alarms when the camera senses motion.
–
IVA/: triggers alarms when IVA is activated.
10.35
Output Options
Allows you to define the following physical outputs and keyboard commands for use in a rule:
–
Output Options 1-3: defines a physical output. The default setting is N.O.
–
Output Option 4 (Alarm Relay): fixed output which is available for use in a rule.
–
Output Options 5-12: used to define a command output for use in a rule. The default
setting is None. Additional options include:
–
None: no defined command.
–
Aux On: defines a standard or custom keyboard ON command (command numbers
1-99).
–
Aux Off: defines a standard or custom keyboard OFF command (command numbers
1-99).
–
Shot: defines a preset scene from shot 1-99.
–
OSD: specifies the on-screen display.
–
Transmit: transmits a message back to the head end (available only with Bilinx and
IP models).
–
Tracking: Alarm input option that turns the tracker on when the alarm is activated.
–
Click the Alarm States link in the left pane to view a status of each alarm.
Physical Output
To define a physical output:
1.
Select Output Option 1 through 3 from the left pane.
2.
Select an alarm output:
–
N.O. (Normally Open, dry contact).
–
N.C. (Normally Closed, dry contact).
3.
Type an alphanumeric name for the output, up to 32 characters.
Alarm Relay
To define an alarm relay:
1.
Select Output Option 4 from the left pane.
2.
Type an alphanumeric name for the output, up to 32 characters.
Rule Definition
Select Output Option 5 through 12 from the left pane, then select a type:
–
None: no trigger event is selected.
–
Aux On: triggers alarms with one respective Aux On command.
–
Aux Off: triggers alarms with one respective Aux Off command.
–
Shot: triggers alarms when the camera is set to one pre-position.
–
Tracking: Alarm input option that turns the tracker on when the alarm is activated.
–
Motion Detection: triggers alarms when the camera senses motion.