VG4 Modular Camera System
Advanced Features | en
49
Bosch Security Systems, Inc.
User’s Manual
F.01U.133.268 | 6.0 | 2010.03
2.
Click the
Online Config
button and then expand
Alarm
.
Figure 7.2
Expanded Alarm Group
3.
Expand Output Options; then click
Output Option 5
.
4.
Select
Tracking
from the Type drop-down list.
5.
Click
Output Option 6
.
6.
Select
Shot
from the Type drop-down list.
7.
Type the number
1
or use the slide bar to specify shot number
1
. (Shot numbers must be
set prior to configuring an alarm rule. See
Section 3.2 Setting Preset Shots, page 30
, for
instructions).
The AutoDome moves to this preposition when the alarm rule is true.
Figure 7.3
Output Option 6 Configuration
8.
Expand Alarm Rule; then click
Alarm Rule 1
.
9.
Click the
Yes
radio button to enable the rule.
10. Type the number
1
or use the slider bar to select
1
for the Input option.
11. Select
Alarm Input 1
from the Input Option drop-down list.
12. Ensure that the Output number is set to
1
.