VG4 Modular Camera System
Advanced Features | en
47
Bosch Security Systems, Inc.
User’s Manual
F.01U.133.268 | 6.0 | 2010.03
3.
Define the Alarm Outputs from the Outputs Setup menu:
a.
Ensure Output 5 is set to
OSD
. (This is the default setting for Output 5.)
b.
Set Output 6 to
Shot 7
.
c.
Set Output 7 to
Transmit
(a Bilinx signal to the head end).
4.
Set up the Alarm Rule (for this example use Rule 1). Select the Inputs from the Rule
Setup menu:
a.
Select
Rule 1
.
b.
Set the first input to
Alarm Input 1
.
5.
Select the outputs:
a.
Set the first output to
OSD
.
b.
Set the second output to
Shot 7
.
c.
Set the third output to
Transmit
.
6.
Enable the rule:
–
Highlight Enabled and select
YES
.
Example 2: Advanced Alarm Rule
Scenario: A 500i Series AutoDome located at an airport is set to AutoPan Between Limits from
the parking garage to the airport terminal. The gate entering the airport has an alarm contact
connected to the AutoDome, and the perimeter fence in the area of the gate has an infrared
(IR) motion detection sensor connected to the AutoDome.
When both the gate contact and motion detector alarms are activated at the same time, we
want the alarm rule to:
1.
Flash an OSD message (***ALARM 2***) on the monitor.
2.
Stop the AutoPan and move the camera to a saved position (Shot 5) viewing the fence.
3.
Turn on AutoTrack.
4.
Transmit a Bilinx signal to the head end system to trigger an alarm response.
The sequence to program this alarm rule example is as follows:
1.
Wire and set the alarm Input(s).
a.
Wire the motion detector to Input 1. (This circuit is normally open.)
b.
Wire the gate alarm contact to Input 5. (This circuit is normally closed.)
2.
From the Inputs Setup menu:
a.
Ensure Input 1 (the motion detector) is set to
N.O.
(This setting is the default for
Input 1.)
b.
Ensure Input 5 (the gate contact) is set to
N.C.
3.
Set the alarm Outputs from the Outputs Setup menu:
a.
Set Output 5 to
OSD
.
b.
Set Output 6 to
Transmit
.
c.
Set Output 7 to
Shot 5
.
d.
Set Output 8 to
AutoTrack
.
4.
Set up the Alarm Rule (for this example use Rule 2). Select the alarm Inputs:
a.
From the Rule Setup menu select
Rule 2
.
b.
Set the first input to
Alarm Input 1
. (The motion detector.)
c.
Set the second input to
Alarm Input 5
. (The gate alarm contact.)
NOTICE!
For instruction on wiring alarm and relay connections, see the
AutoDome Modular
Camera System Installation Manual
.