48
en | Advanced Features
VG4 Modular Camera System
F.01U.133.268 | 6.0 | 2010.03
User’s Manual
Bosch Security Systems, Inc.
5.
Select the alarm Outputs:
a.
Set the first output to
OSD
.
b.
Set the second output to
Shot 5
viewing the fence.
c.
Set the third output to
AutoTrack
and select Latched.
d.
Set the fourth output to
Transmit
(a Bilinx signal to the headend).
6.
Enable the alarm Rule:
–
Highlight Enabled and select
YES
.
Example 3: Advanced Alarm Rule using AutoTrack
The following example explains how to set an alarm rule that moves the camera to a preset
position and then activates the AutoTrack feature to track an intruder after an alarm is
triggered. This example uses the Configuration Tool for Imaging Devices (CTFID) software
tool. Refer to the
Configuration Tool for Imaging Devices User Guide
, available at
www.boschsecurity.com.
1.
Launch the CTFID software from a computer that is connected to a VG4 AutoDome.
Figure 7.1
CTFID Overview Window