Code
Name
Setting range
Default Min.
Attri.
F2.16 X1 input
0: No function assigned from ASF
1: Pressure command selection bit0
2: Pressure command selection bit1
3: p/Q parameter set selection
4: Flow command selection
5: Master / slave mode switch
6: Oil filter warning
7: Oil level warning
8: Oil temperature warning
9: Oil filter error
10: Oil level error
11: Oil temperature error
12: Oil level / temperature error
13: Oil filter warning inverse
14: Oil level warning inverse
15: Oil filter error inverse
16: Oil level / temperature error in-
verse
17: Reserved
18: Reserved
19: Reserved
20: Pressure drop compensation trig-
ger
21: Pressure overshoot compensation
trigger
22: Drive enable for myCro
0
(RUN)
-
Stop
F2.17 X2 input
0
(Error
reset)
-
Stop
F2.18 X3 input
0
-
Stop
F2.19 X4 input
0
-
Stop
F2.20 X5 input
0
-
Stop
F2.21 EX1 input
0
-
Stop
F2.22 EX2 input
0
-
Stop
F2.23 EX3 input
0
-
Stop
F2.24 EX4 input
0
-
Stop
F2.25 EX5 input
0
-
Stop
F2.31 AO1 output
0: No function assigned from ASF
1: Pressure command (scaled by
F2.04)
2: Pressure feedback (scaled by
F2.06)
3: Setting speed (include direction)
(scaled by F2.08)
4: Output speed (include direction)
(scaled by F2.08)
0
-
Run
F2.32 EAO output
0
-
Run
Bosch Rexroth AG
FcP 5020 Parameter List
FcP 5020
68/83
DOK-RCON03-FCP5020****-QU04-EN-P