Code
Name
Setting range
Default Min. Attri.
F2.07 Pressure feedback null offset
in V or mA
0.0...5.0 V, mA
4.0
(mA)
0.1
Stop
F2.10 Pressure sensor type
0: Others
1: HM20-2X/10-C
2: HM20-2X/50-C
3: HM20-2X/100-C
4: HM20-2X/160-C
5: HM20-2X/250-C
6: HM20-2X/315-C
7: HM20-2X/400-C
8: HM20-2X/630-C
9: Other 4...20mA pressure sensor
10: Reserved
11: HM20-2X/10-H
12: HM20-2X/50-H
13: HM20-2X/100-H
14: HM20-2X/160-H
15: HM20-2X/250-H
16: HM20-2X/315-H
17: HM20-2X/400-H
18: HM20-2X/630-H
19: Other 0...10V pressure sensor
3
-
Stop
Tab. 7-4: Parameter list of HM20 pressure sensor auto selection
Bosch Rexroth AG
Block Diagram of Main Functions
FcP 5020
26/83
DOK-RCON03-FCP5020****-QU04-EN-P