Pin assignment
Power
Encoder
D
Pol pattern M40
U1
A1
Pol pattern M17
1
+UB
V1
A2
2
n.c.
W1
A3
3
DATA+
PE
4
DATA-
5
n.c.
5
n.c.
6
n.c.
6
n.c.
7
BD(+)
7
n.c.
8
BD(-)
8
n.c.
9
n.c.
9
GND
Tab. 7-6:
MS2Exx-xxxxx-xxVxx-xxxxx-xx Pin assignment
7.2.4
Ground conductor
Motors for hazardous areas must be grounded via a separate ground con‐
ductor and a grounding conductor within the motor power cable. An additional
connection clamp is provided on the motor flange to connect the grounding
conductor.
Ground connection
Nominal cross-section 4 mm²
Clamping range 4 mm² (fine-wired); 6 mm² (single stranded)
Max. tightening torque 2 Nm
Tab. 7-7:
Junction for grounding conductor
7.2.5
Protective cable glands for connectors
At delivery, the connectors are locked with protective cable glands. The cable
gland protects the motor from humidity, dirt and mechanical damage.
Fig. 7-2:
Protective cable glands
Remove the protective cable glands right before connecting the mating con‐
nector. Always use protective cable glands, if no plug-connector is connected
(e.g. storage, maintenance, ...).
7.2.6
Connect flange socket
Observe when connecting the flange socket:
●
Connect or disconnect plug connections only in de-energized, dry and
clean state.
●
Connect the motor with the ready-made connection cable.
MS2E Synchronous Servomotors acc. to ATEX Directive
2014/34/EU
45/65
Assembly
R911387136_Edition 02 Bosch Rexroth AG