42/56
Press modules Type IH04
| Disassembly and replacement
Bosch Rexroth AG, Edition 08.2021, RE 63124-B
12.3 Disassembly process
WARNING
Pressurized and energized system parts!
Danger to life! Risk of injury caused by electric shock!
▶ Ensure that the hydraulic system is depressurized and the electrical control
de-energized before disassembly.
CAUTION
Falling of not fully secured press modules
Risk of injury!
▶ Secure the press module to be disassembled against falling down.
Leaking hydraulic fluid!
Risk of injury! Risk of falling!
▶ After disassembly, seal the hydraulic fluid bores with suitable cap elements.
▶ Immediately remove leaked hydraulic fluid and dispose of it properly.
▶ Have sufficiently dimensioned collecting containers, residue-free industrial
wipes and hydraulic fluid binding materials ready in order to collect or bind
leaking hydraulic fluid.
For disassembling the press module, you should proceed as follows:
▶ Get the product-specific documentation ready.
▶ Observe the safety instructions applicable to transport and assembly,
see chapters 6 and 7.
▶ Ensure that the hydraulic system is depressurized.
▶ Check whether the press module has cooled down sufficiently so that it can be
disassembled in a risk-free manner.
▶ De-energize the overall machine/system.
▶ Loosen and/or separate the electric connectors and connections.
▶ Disconnect the pipes/hoses and collect any leaking hydraulic fluid in the
prepared collecting container (drip-tray).
▶ Shut off the supply (P, T and Y) from the tank to the press module.
▶ Completely drain the press module.
▶ Close all openings.
– To do this, seal the connections with suitable plug screws and flange covers.
▶ Make sure that the individual components of the press module as well as the
attached components are not damaged during disassembly.
▶ Screw the ring bolts, see Fig. 3, hand-tight into the tapped holes provided
and attach lifting slings or load chains to them so that the press module
is plane-parallel to the contact surface when it is lifted.
– The weight is shown on the installation drawing.
▶ Loosen the mounting screws diagonally, crosswise, and remove them.
▶ Now slowly remove the press module from the contact surface.