12/56
Press modules Type IH04
| Safety instructions
Bosch Rexroth AG, Edition 08.2021, RE 63124-B
2.6 Product- and technology-dependent safety instructions
The following safety instructions apply to chapters 6 to 15.
WARNING
Uncontrolled moving parts due to incorrect control and unexpected start-up
when safety functions are bypassed or functional safety is not observed!
Danger to life! Risk of injury! Danger of entanglement, ejection or crushing of
persons!
▶ Note the requirements of EN ISO 13849 as well as the relevant product
standards EN ISO 16092 and EN 289 when setting up functional safety.
▶ Mount EMERGENCY stop devices, a safety door, light barriers, light curtains
and/or two-hand control device.
▶ Immediately replace defective safety-related components.
Leakage of (pressurized) hydraulic fluid and oil mist!
Danger to life! Risk of injury! Explosion hazard, risk of fire, health hazard,
environmental pollution! Damage to property!
▶ Switch the machine/system off immediately (emergency off switch).
▶ Identify and remedy the leakage.
▶ Never try to stop or seal the leakage or the oil jet using a cloth.
▶ Avoid direct contact with the leaking hydraulic fluid.
▶ Use your personal protective equipment, e. g safety goggles.
▶ Do not use the press module in areas with open fire (e.g. ignition sources ...)
and only at a sufficient distance to hot heat sources.
▶ When dealing with hydraulic fluids, you must implicitly observe the information
of the hydraulic fluid manufacturer.
Unexpected press movements due to functional failures (overheating of the
solenoid coil, drift error in the integrated electronics of proportional valves)
of the press module when the intended maximum temperatures are exceeded!
Danger to life! Risk of injury! Damage to property!
▶ Only use the press module within the approved environmental and hydraulic
fluid temperature range.
Rapid aging of seals and permanent leakage of valves when the press module is
used outside the approved temperature range!
Danger to life! Risk of injury! Damage to property!
▶ Only use the press module within the approved hydraulic fluid
temperature range.
▶ In case of leakage, immediately replace damaged seal rings and/or the
affected valve.