RE 63124-B, Edition: 08.2021, Bosch Rexroth AG
Troubleshooting |
Press modules Type IH04 47/56
Table 9: Fault table
Fault
Possible cause
Remedy
External leakage
Seals at connection surface damaged
▶ Remove the hydraulic component and replace it.
Other leakage
▶ Replace the leaking hydraulic valves.
No function
Electrical connection interrupted
▶ Check whether the electrical plug-in connectors are
correctly and completely mounted.
Defective limit switch or no feedback
information of position monitoring
▶ Replace the complete defective component.
▶ Return the component for repair.
▶ Have repair works of components with position
monitoring performed by authorized personnel only.
Cable break
▶ Replace the connection cable.
Replace the connection cable
▶ Replace the solenoid connection plug.
In case of faults in individual components, please consult the documentation of
the respective component.