Technical data 77/84
3 842 540 399/2016-11, MIT: ID 200,
Bosch Rexroth AG
9.4 Transmission times
Reading the data carrier MDT../2K-H with ID 200/A-HF through to the control
*
User data bytes
Cycles n
Time ms
User data bytes
Cycles n
Time ms
8
76
76
208
403
403
16
85
85
216
404
404
24
89
89
224
408
408
32
91
91
232
484
484
40
97
97
240
493
493
48
98
98
248
497
497
56
102
102
256
499
499
64
178
178
264
505
505
72
187
187
272
506
506
80
191
191
280
510
510
88
193
193
288
586
586
96
199
199
296
595
595
104
200
200
304
599
599
112
204
204
312
601
601
120
280
280
320
607
607
128
289
289
328
608
608
136
293
293
336
612
612
144
295
295
344
688
688
152
301
301
360
697
697
160
302
302
384
701
701
168
306
306
416
703
703
176
382
382
456
709
709
184
391
391
504
710
710
192
395
395
560
714
714
200
397
397
* DataHoldTime (10ms): 2
GSD I/O bytes: 64/64
PLC cycle ms: 1
Fig. 24:
t
= time
N
= user data quantity
EN
GLISH