Communication with ID 200/C-PDP 41/84
3 842 540 399/2016-11, MIT: ID 200,
Bosch Rexroth AG
7.3.6
System commands
change tag (CT)
Command:
Byte
Table of contents
Bit no.
7
6
5
4
3
2
1
0
Byte 0
Command code (04h)
0
0
0
0
0
1
0
0
Byte 1
reserved/RFID channel/toggle bit
–
–
–
–
<RFIDChannel> <T>
Byte 2
Data carrier type in ASCII
<TagType> (High Byte)
Byte 3
Data carrier type in ASCII
<TagType> (Low Byte)
Byte 4
unused
–
–
–
–
–
–
–
–
Byte 5
unused
–
–
–
–
–
–
–
–
Byte 6
unused
–
–
–
–
–
–
–
–
Byte 7
unused
–
–
–
–
–
–
–
–
Reply:
Byte
Table of contents
Bit no.
7
6
5
4
3
2
1
0
Byte 0
Command code (04h)
0
0
0
0
0
1
0
0
Byte 1
reserved/RFID channel/toggle bit
–
–
–
–
<RFIDChannel> <T>
Byte 2
Status
<Status>
Byte 3
Reply counter
<ReplyCounter>
Byte 4
unused
–
–
–
–
–
–
–
–
Byte 5
unused
–
–
–
–
–
–
–
–
Byte 6
unused
–
–
–
–
–
–
–
–
Byte 7
unused
–
–
–
–
–
–
–
–
This command tells the antenna on the relevant channel which data carrier type it is
communicating with. This setting is saved non-volatile in the communication module.
EN