Communication with ID 200/C-PDP 31/84
3 842 540 399/2016-11, MIT: ID 200,
Bosch Rexroth AG
If an MDT (e.g. from a PROFIBUS application) contains data outside the range
listed above, unusual characters (“hieroglyphics”) may appear in the terminal
when reading out. This data can not be evaluated on the terminal.
Example for writing data in a MDT:
The command:
sw100000231323334#<ENTER>
writes the bytes 33h 31h 33h 32h 33h 33h 33h 34h from address 0 in the MDT
memory via the antennas on RFID channel 1.
7.1.2
System commands
The commands in the list are described in detail in section 7.3.5.
Command Description
Parameter 1
Parameter 2
Parameter 3
CT
Change Tag
Set tag type
<RFIDChannel>
1
2
<TagType>
15: MDT-L
21: MDT/112-H
33: MDT/2K-H
Reply
<Status>
04
<RFIDChannel>
QU
Quit
End enhanced
command
<RFIDChannel>
1
2
Reply
<Status>
02
<RFIDChannel>
RS
Reset
Restart the
system
Reply
No reply, as the communication module is restarting
Comment
When using the web server in ID 200/C-PDP, the network connec-
tion of the PC must be disconnected and reconnected so that the
website is accessible again.
MM
Multiplex Mode
<Switch>
1: MM On
0: MM Off
Reply
<Status>
9B
TM
Trigger Mode
<Sensorchannel>
≠
<RFIDChannel>
<RFIDChannel>
≠
<Sensorchannel>
<Triggermode>
0 : TM off
1 : TM on
2 : TM inverted
Reply
<Status>
9C
<Sensorchannel>
EN
GLISH