Function
code
Name
Setting
range
Min.
unit
Factory
default
Attributes
[S2.03] Rated motor voltage
0 ~ 480 V
1 V
Depending
on model
Stop
[S2.04] Rated motor current
0.1 ~ 1000.0 A
0.1 A
Depending
on model
Stop
Fig.7-2: Basic parameter fast setting
7.4
Restore Parameters to Factory Defaults
If the frequency converter fails to run the motor due to incorrect parameter settings, a
simple solution is to initialize the parameters to factory defaults. Setting [b0.05]=1 will
start initialization.
Please be sure that the parameter settings match with the motor and the field applica‐
tions after factory defaults restore. Adjust the parameter settings after factory defaults
restore if necessary.
Operating frequency
Set by the potentiometer ([b1.00])
Acc./Dec. time
Linear, Acc. for 5s / Dec. for 5s ([b1.20], [b1.21])
Protection mode in case
of motor overload and
overheat
Motor rated current [S2.04], thermal motor time constant
[S2.23], low speed derating frequency [E4.04], and zero
speed load [E4.05]
Panel operation
Run, Stop buttons as commands, potentiometer as frequen‐
cy setting source
V/F curve mode
linear
Fig.7-3: Factory defaults
DOK-RCON03-EFC-3600***-IT01-EN-P
Rexroth Frequency Converter EFC 3600
Bosch Rexroth AG
Commissioning
51/235
Содержание Rexroth EFC 3600
Страница 6: ...Bosch Rexroth AG DOK RCON03 EFC 3600 IT01 EN P Rexroth Frequency Converter EFC 3600 IV 235 ...
Страница 232: ...230 235 ...
Страница 236: ...Bosch Rexroth AG DOK RCON03 EFC 3600 IT01 EN P Rexroth Frequency Converter EFC 3600 234 235 ...
Страница 237: ...Notes DOK RCON03 EFC 3600 IT01 EN P Rexroth Frequency Converter EFC 3600 Bosch Rexroth AG ...
Страница 238: ...ООО Комфорт Компани 03038 г Киев Украина ул Н Гринченко 4 тел 38 044 362 3676 info comfort co com comfort co com ...