Motor thermal protection
Function
code
Name
Setting range
Min.
unit
Factory
default Attribute
S2.20 Sensor type
0: PTC; 1: NTC
1
0
STOP
S2.21 Input channel of motor tem‐
perature
0: Invalid; 1: AIV
1
0
S2.22 Protection level
0.0 ~ 10.0
0.1
2.0
STOP
S2.23 Thermal motor time constant 0.0 ~ 400.0 min
0.1
on model STOP
S2.24
~
S2.29
Reserved
–
–
–
–
Encoder
Function code
Name
Setting range
Min.
unit
Factory
default
Attribute
S2.30 ~ S2.39 Reserved
–
–
–
–
17.2.6
Group S3: Running Parameters
Jogging parameters
Function
code
Name
Setting range
Min.
unit
Factory
default Attribute
S3.00 Jogging frequency
0.00 ~ [b1.05] 0.01 Hz 5.00 Hz
RUN/
STOP
S3.01 Jogging acceleration time
0.1 ~ 6000.0s
0.1s
5.0s
RUN/
STOP
S3.02 Jogging deceleration time
0.1 ~ 6000.0s
0.1s
5.0s
RUN/
STOP
S3.03
~
S3.04
Reserved
–
–
–
–