01.2015, USL00010,
Bosch Rexroth Corp.
12 Motor (continued)
12.2.1 Steps for configuring the linear motor from database: (continued)
3. Enter the primary and secondary type codes based on the below table, then select the
Linear and Synchronous options.
System size Carriage length
Primary part
Secondary part
CKL 110
180 mm
MCP030B-V180-NI-xxCN-NNNN
MCS030-3S-xxxx-NNNN
240 mm
MCP030C-V180-NI-xxCN-NNNN
MCS030-3S-xxxx-NNNN
300 mm
MCP030D-V180-NI-xxCN-NNNN
MCS030-3S-xxxx-NNNN
CKL 145
244 mm
MCP040C-V300-NI-xxCN-NNNN
MCS040-3S-xxxx-NNNN
364 mm
MCP040E-V300-NI-xxCN-NNNN
MCS040-3S-xxxx-NNNN
484 mm
MCP040G-V300-NI-xxCN-NNNN
MCS040-3S-xxxx-NNNN
CKL 200
237 mm
MCP070C-V300-NI-xxCN-NNNN
MCS070-3S-xxxx-NNNN
297 mm
MCP070D-V300-NI-xxCN-NNNN
MCS070-3S-xxxx-NNNN
417 mm
MCP070F-V300-NI-xxCN-NNNN
MCS070-3S-xxxx-NNNN
xx: L0 = digital Hall, L1 = analog Hall, N0 = without Hall
xxxx: 0120, 0180, 0300 = secondary part length mm, select any value
4. Press the DB → Drive button to download the motor parameters to the drive.
23
Motor