5.5
Temporary Connection of Further IDE Devices
5.5.1
General Information
It is possible to connect further IDE devices to the BTV 20.4 without changing
the cabling of the internal HDD. The following figure shows the connection for
the power supply cable and the IDE port:
Fig.5-24:
Position of the temporary connections
5.5.2
Connection for the Power Supply Cable
To provide power to the IDE device an additional external voltage source is to
be connected to the slot CPU card. To do so, use a standard power supply
cable for 5.25" PC drives.
The pin assignment is as follows:
Fig.5-25:
Connection for the power supply cable
PIN
Color
Meaning
1
Yellow orange
+12 V
2
Black
GND
3
Black
GND
4
Red
+5 V
Fig.5-26:
Pin assignment