Installation 29/68
RE 92105-01-B/06.2017, A4CSG, Series 3x,
Bosch Rexroth AG
Recommended installation position: 1 and 2.
1
2
4
5
S
R(L)
h
min
h
t min
SB
S
T
h
min
h
t min
SB
3
S
h
min
h
t min
SB
K
2
S
h
min
h
t min
SB
K
3
S
T
h
min
h
t min
SB
U
Fig. 8: Below-reservoir installation A4CSG with installation positions 1–5
T, R(l),
K
2
, K
3
Highest drain port
(leakage)
h
t min
Minimum required immersion
depth (200 mm)
S
Suction port
h
min
Minimum required distance to
reservoir bottom (100 mm)
SB
Baffle (baffle plate)
Table 8: Below-reservoir installation
Installation position
Filling/air bleeding the housing
1)
1 (drive shaft horizontal)
R
(
l
)
2 (drive shaft horizontal)
Plug
T
;
R
(
l
)
3 (drive shaft horizontal)
Plug
K2
;
R
(
l
)
4 (drive shaft horizontal)
Plug
K3
;
R
(
l
)
5 (drive shaft vertically upward)
Plug
T
;
R
(
l
)
1)
To air bleed the stroking chamber, use the highest port on the control.
7.3.2 Above-reservoir installation
Above-reservoir installation means that the axial piston unit is installed above the
minimum fluid level of the reservoir.