Installation 31/68
RE 92105-01-B/06.2017, A4CSG, Series 3x,
Bosch Rexroth AG
6
7
9
10
8
h
min
h
t min
SB
S
R(L)
h
min
h
t min
SB
h
S max
L
1
L
2
h
S max
L
1
L
2
S
S
S
K
2
h
min
h
t min
SB
h
S max
L
1
L
2
h
min
h
t min
SB
h
S max
L
1
L
2
S
T
h
min
h
t min
SB
h
S max
L
1
L
2
T
K
3
Fig. 9: Above-reservoir installation A4CSG with installation positions 6–10
l
1
, l
2
Filling / air bleeding
h
t min
Minimum required immersion depth
(200 mm)
T, R(l),
K
2
, K
3
Highest drain port
(leakage)
h
min
Minimum required distance to
reservoir bottom (100 mm)
S
Suction port
h
S max
Maximum permissible suction height
(800 mm)
SB
Baffle (baffle plate)
Table 9: Above-reservoir installation
Installation position
Filling/air bleeding the housing
1)
6 (drive shaft horizontal)
R
(
l
)
7 (drive shaft horizontal)
Plug
T
;
R
(
l
)
8 (drive shaft horizontal)
Plug
K2
;
R
(
l
)
9 (drive shaft horizontal)
Plug
K3
;
R
(
l
)
10 (drive shaft vertically upward)
Plug
T
;
R
(
l
)
1)
To air bleed the stroking chamber, use the highest port on the control.