background image

PR111B-PR112B Installer Reference Guide

6

Bosch Security Systems    09/11    PR111B-PR112BIRG  FTR1.1

Connection Diagram

PR111 LAN Reader

P/N:

MFG: 

S/N:

PR111B

30-Jul-2011

00542754

N12138

To C

on

t

rol

 Pa

ne

 

 

   .

Lock

Output

EGRESS

INPUT

N/O

BK
RD

WH

BL

YL

GN

M

O

D

U

LE

  L

A

N

CONTR

OL  P

ANEL

-

A

B

+

TO

DOOR 

LOCK

+

-

+12V

DF70

N/O

COM

N/C

CM444 Relay Card

RED

BLACK

WHITE

BLUE

YELLOW

GREEN

= LAN +

= LAN -

= LAN A

= LAN B

= LOCK

= EGRESS

Wiring Legend

DOOR

LOCK

PROTECTION

DIODE

+

CM444B RELAY CARD

+

Egress

Input

RD

CM720B or CM723B 

Power Supply

(Battery backed up)

+    -

Figure 4: PR111B and PR112B Connection Diagram

The optional CM444B relay module provides 

 an easy way to interface the readers lock 

output to the door lock. 

 

Because of its small physical size  

(12.5 x 46 x 12mm) it can be easily located 

in the wall cavity if required.

The egress input 

 is low (0V) to trigger.   

 

Disable via panel  

programming if not  

being used.

Address Select Switch.  Keypads and LAN 

Readers must be set to a unique address as 

per “Table 2: Address Table” on page 2  

All LAN Readers are supplied from 

the factory set to Address 1.

 

i

Note

  You must power cycle the panel or perform

a LAN scan after connecting the PR111B or 

PR112B for the system to initialise the reader.

Make sure that the 

keypad buzzer opening 

is not blocked   

during installation 

or the volume will be 

greatly reduced. 

Содержание PR111B

Страница 1: ...PR111B and PR112B External LAN Reader Modules Security System Installer Reference Guide EN Security Systems ...

Страница 2: ...ed to the system must be assigned a unique address on the LAN The PR111B and PR112B readers include a rotary address switch for quick selection The following table shows the address setting for each reader as well as the number of keypad reader devices each panel can support Reader Compatibility Panels Supported Version Keypads Supported Solution 16i 2 19 Up to 8 Solution 16X 2 00 Up to 8 Solution...

Страница 3: ...both depending on the installation requirements As there is no LCD display on the readers feedback is provided via the red green and blue indicators and the reader sounder The readers also include an egress input and lock output which can be used to control door access if required i Note Using the on board lock output is not recommend ed when the reader is being used on an external wall of the bui...

Страница 4: ...lowest level See the Devices Keypads Readers Commands menu in panel programming i Note Setting the reader volume to off will stop all audible warning signals at the reader Reader Alert Tones Event Alert Tone Emitted Fire Alarm If the system registers a fire alarm the reader will sound 3 short beeps fol lowed by a 1 5 second pause This will repeat until reset by the user or until the siren run time...

Страница 5: ...d open collector transistor that can be used to operate a relay to control the door lock The output will go from open to low for fixed 5 seconds whenever the associated access group or door assignment is triggered i Note The on board lock output will operate for a fixed time period of 5 seconds when triggered If a dif ferent time is required then you should use another output on the system to oper...

Страница 6: ...tion Diagram The optional CM444B relay module provides an easy way to interface the readers lock output to the door lock Because of its small physical size 12 5 x 46 x 12mm it can be easily located in the wall cavity if required The egress input is low 0V to trigger Disable via panel programming if not being used Address Select Switch Keypads and LAN Readers must be set to a unique address as per ...

Страница 7: ...tor output 500mA Egress Input Low to trigger Can be disabled via software control Dimensions 44mm W 21mm D 114mm H CM444B 46mm W 12 5mm D 12mm H Environment 30 to 55 C RH 5 to 85 at 30 C non condensing Fixing Method The PR111B and PR112B should be mounted on a sturdy vertical wall using fixtures appropriate for the wall construction type Warranty 3 years from date of manufacture return to base N12...

Страница 8: ...Bosch Security Systems 25 Huntingwood Drive Huntingwood NSW 2148 Australia Phone 612 9672 1777 Facsimile 612 9672 1717 2011 Bosch Security Systems PR111B PR112BIRG Issue FTR1 1 ...

Отзывы: