PR111B-PR112B Installer Reference Guide

4

Bosch Security Systems    09/11    PR111B-PR112BIRG  FTR1.1

To have the reader control an area on the alarm system 

you must assign the reader to a home area.  See the 

Devices-Keypads & Readers-Home Area menu option 

in panel programming.  If alarm system control is not 

required then you should set the home area option to 

No Area. 

i

Note

  When the reader has been configured to do alarm 

area control only, the blue indicator will remain off 

at all times.

To have the reader control an output (door) on the 

system you must assign the reader to an access group.  

See the Devices-Keypads & Readers-Access Group menu 

option in panel programming.  

Once assigned,  the on-board Lock output and Egress in-

put are automatically assigned to the same access group 

as the reader.

LED Operation For Door Control

Led

Condition

Meaning

Blue

On

Door Locked

Blue

Fast Flash

Door Unlocked

Blue

Continuous 

Fast Flash

Door manually unlocked 

or overridden.

Blue

2 Flashes 

Door automatically 

unlocked by schedule or 

time zone.

Red & 

Green

Alternate 

Flashing

Reader initialising during 

power up or LAN scan.

Blue

Off

Access Group not pro-

grammed or reader not 

powered.

Table 4: Reader LED‘s - Access Group Door Control

If both alarm area and door control is required, you must  

assign a home area and an access group to the reader.  

i

Note

  When the reader has been configured to do door 

control only, the green and red indicators will re-

main off at all times.

Alert Tones

The reader emits several distinct tones to alert you to 

particular system events.  The volume level cannot be 

adjusted on the external LAN readers however it can be 

turned off via panel programming by setting the reader 

volume to the lowest level.  See the Devices-Keypads & 

Readers-Commands menu in panel programming. 

i

Note

  Setting the reader volume to off will stop all audible 

warning signals at the reader.

Reader Alert Tones

Event

Alert Tone Emitted

Fire

Alarm

If the system registers a fire alarm, the 

reader will sound 3 short beeps fol-

lowed by a 1.5 second pause.  This will 

repeat until reset by the user or until 

the siren run time expires.

Burglary 

Alarm

If the system registers a burglary 

alarm, the reader will sound a continu-

ous siren tone until reset by a user or 

until the siren run time expires.

Trouble

If a system trouble condition occurs, 

the reader will sound 4 x fast short 

beeps followed by a 5 second pause 

and will repeat this tone until the user 

acknowledges the trouble  

condition from a display keypad

Exit

Delay

The exit delay warning will sound 1 

short beep every second when the 

area the reader has been assigned to 

is armed.  During the last 10  

seconds of exit time the warning tone 

will speed up indicating that the time 

has nearly expired.

Entry

Delay

The hi/lo entry delay warning tone will 

sound once every second when an 

entry delay zone in the area the reader 

has been assigned to is triggered.  If 

the system is not disarmed before the 

entry time expires then an alarm will 

occur. 

Error

If an invalid token is presented to the 

reader the keypad will sound a 2 sec-

ond warning tone indicating that the 

token was rejected for some reason. 

See the panel log for more details.

Chime 

Alert

If chime mode is active then the read-

er will sound fast short beeps to alert 

the user when a zone programmed for 

chime is opened.   Chime mode is only 

applicable when the area is disarmed.

Table 5: Reader Tones

i

Note

  When readers are installed outside the premises, 

you may prefer that the alert tones are disabled.  

See the Devices-Keypads & Readers-Indicator Op-

tions menu in panel programming to disable these 

features. 

Содержание PR111B

Страница 1: ...PR111B and PR112B External LAN Reader Modules Security System Installer Reference Guide EN Security Systems ...

Страница 2: ...ed to the system must be assigned a unique address on the LAN The PR111B and PR112B readers include a rotary address switch for quick selection The following table shows the address setting for each reader as well as the number of keypad reader devices each panel can support Reader Compatibility Panels Supported Version Keypads Supported Solution 16i 2 19 Up to 8 Solution 16X 2 00 Up to 8 Solution...

Страница 3: ...both depending on the installation requirements As there is no LCD display on the readers feedback is provided via the red green and blue indicators and the reader sounder The readers also include an egress input and lock output which can be used to control door access if required i Note Using the on board lock output is not recommend ed when the reader is being used on an external wall of the bui...

Страница 4: ...lowest level See the Devices Keypads Readers Commands menu in panel programming i Note Setting the reader volume to off will stop all audible warning signals at the reader Reader Alert Tones Event Alert Tone Emitted Fire Alarm If the system registers a fire alarm the reader will sound 3 short beeps fol lowed by a 1 5 second pause This will repeat until reset by the user or until the siren run time...

Страница 5: ...d open collector transistor that can be used to operate a relay to control the door lock The output will go from open to low for fixed 5 seconds whenever the associated access group or door assignment is triggered i Note The on board lock output will operate for a fixed time period of 5 seconds when triggered If a dif ferent time is required then you should use another output on the system to oper...

Страница 6: ...tion Diagram The optional CM444B relay module provides an easy way to interface the readers lock output to the door lock Because of its small physical size 12 5 x 46 x 12mm it can be easily located in the wall cavity if required The egress input is low 0V to trigger Disable via panel programming if not being used Address Select Switch Keypads and LAN Readers must be set to a unique address as per ...

Страница 7: ...tor output 500mA Egress Input Low to trigger Can be disabled via software control Dimensions 44mm W 21mm D 114mm H CM444B 46mm W 12 5mm D 12mm H Environment 30 to 55 C RH 5 to 85 at 30 C non condensing Fixing Method The PR111B and PR112B should be mounted on a sturdy vertical wall using fixtures appropriate for the wall construction type Warranty 3 years from date of manufacture return to base N12...

Страница 8: ...Bosch Security Systems 25 Huntingwood Drive Huntingwood NSW 2148 Australia Phone 612 9672 1777 Facsimile 612 9672 1717 2011 Bosch Security Systems PR111B PR112BIRG Issue FTR1 1 ...

Отзывы: