PR111B-PR112B Installer Reference Guide

2

Bosch Security Systems    09/11    PR111B-PR112BIRG  FTR1.1

The PR111B and PR112B external LAN readers feature our proprietary 40 bit transmission format and can be used 

to provide alarm and or access control functionality when used on selected Solution 

security control panels.  
Constructed from UV stabilised ASA plastic, the external readers provide a high level 

of vandal resistance and are weather resistant to IP66 making them ideal for outdoor 

installations.  

The PR111B and PR112B readers include red, green and blue indicators which are 

used to show area and or door lock status at all times.
The reader connects to the control panel via the RS485 encrypted LAN and occupies 

a standard keypad position in the panel configuration.  Various options can be con-

figured via the Devices - Keypad & Readers menu in panel programming.  User access 

events are stored in the panel log and can also be reported if required. 

Reader Addressing

Each reader fitted to the system must be assigned a unique address on the LAN.   

The PR111B and PR112B readers include a rotary address switch for quick selection.  The following table shows the  

address setting for each reader as well as the number of keypad, reader devices each panel can support.

Reader Compatibility

Panels Supported

Version

Keypads Supported

Solution 16i

2.19

Up to 8

Solution 16X

2.00

Up to 8

Solution 144

2.00

Up to 16

Solution E

2.00

Up to 16

Table 1: LAN Reader Compatibility

Weatherproof external LAN Readers

PR111B - Black and PR112B - White

Figure 1: PR111B Reader

Reader Address Setting

Address No Keypad No

So

lu

ti

o

n

 1

6

P

an

el

So

lu

ti

o

n

 1

6

X

 P

an

el

So

lu

ti

o

n

 1

4

4

 P

an

el

So

lu

ti

o

n

 E

 P

an

el

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

9

9

10

10

11

11

12

12

13

13

14

14

15

15

16

16

Table 2: Address Table

Figure 2: Address Switch

i

Note

  Only 1 reader can be assigned to each address.  All 

readers are supplied from the factory set to address 

1.  You must power cycle the panel or perform a 

LAN scan whenever you change the reader address.

Box Contents

The PR111B and PR112B contains the following parts.

Reader Base Unit
Reader Cover
Mounting Template
Instruction Sheet
1 x (M3 x 6mm) Hex Screw
1 x 2mm Hex Key

Содержание PR111B

Страница 1: ...PR111B and PR112B External LAN Reader Modules Security System Installer Reference Guide EN Security Systems ...

Страница 2: ...ed to the system must be assigned a unique address on the LAN The PR111B and PR112B readers include a rotary address switch for quick selection The following table shows the address setting for each reader as well as the number of keypad reader devices each panel can support Reader Compatibility Panels Supported Version Keypads Supported Solution 16i 2 19 Up to 8 Solution 16X 2 00 Up to 8 Solution...

Страница 3: ...both depending on the installation requirements As there is no LCD display on the readers feedback is provided via the red green and blue indicators and the reader sounder The readers also include an egress input and lock output which can be used to control door access if required i Note Using the on board lock output is not recommend ed when the reader is being used on an external wall of the bui...

Страница 4: ...lowest level See the Devices Keypads Readers Commands menu in panel programming i Note Setting the reader volume to off will stop all audible warning signals at the reader Reader Alert Tones Event Alert Tone Emitted Fire Alarm If the system registers a fire alarm the reader will sound 3 short beeps fol lowed by a 1 5 second pause This will repeat until reset by the user or until the siren run time...

Страница 5: ...d open collector transistor that can be used to operate a relay to control the door lock The output will go from open to low for fixed 5 seconds whenever the associated access group or door assignment is triggered i Note The on board lock output will operate for a fixed time period of 5 seconds when triggered If a dif ferent time is required then you should use another output on the system to oper...

Страница 6: ...tion Diagram The optional CM444B relay module provides an easy way to interface the readers lock output to the door lock Because of its small physical size 12 5 x 46 x 12mm it can be easily located in the wall cavity if required The egress input is low 0V to trigger Disable via panel programming if not being used Address Select Switch Keypads and LAN Readers must be set to a unique address as per ...

Страница 7: ...tor output 500mA Egress Input Low to trigger Can be disabled via software control Dimensions 44mm W 21mm D 114mm H CM444B 46mm W 12 5mm D 12mm H Environment 30 to 55 C RH 5 to 85 at 30 C non condensing Fixing Method The PR111B and PR112B should be mounted on a sturdy vertical wall using fixtures appropriate for the wall construction type Warranty 3 years from date of manufacture return to base N12...

Страница 8: ...Bosch Security Systems 25 Huntingwood Drive Huntingwood NSW 2148 Australia Phone 612 9672 1777 Facsimile 612 9672 1717 2011 Bosch Security Systems PR111B PR112BIRG Issue FTR1 1 ...

Отзывы: