168
en | Troubleshooting
Bosch Video Management System
Configuration Client | V3 | 2010.07
Configuration Manual
Bosch Sicherheitssysteme GmbH
4.
Edit the Operator Client configuration file:
C:\<Bosch installation
directory>\Bosch\VMS\bin\OperatorClient.exe.config
5.
Look for a line like the following:
<add key="MicrophoneInputNr" value="2"/>
If the number for the microphone differs from the number found in the log file, change
the number here to the number in the log file. In this example, change to number 1.
6.
Restart Operator Client.
Now the microphone is used as input source.
26.4
Reducing the number of Allegiant cameras
You need the Allegiant
Master Control Software
to edit the Allegiant file.
To reduce the number of Allegiant cameras:
1.
Start the Master Control Software.
2.
Open the Allegiant file.
3.
Click the
Camera
tab.
4.
Mark the cameras that are not required.
5.
On the
Edit
menu, click
Delete
.
6.
Save the file. The file size remains unchanged.
7.
Repeat the last step for monitors that you do not need. Click the
Monitors
tab.
8.
Import this file in Bosch Video Management System (see
Section 6.3 Adding a device,
page 23
).