Bosch Video Management System
Concepts | en
159
Bosch Sicherheitssysteme GmbH
Configuration Manual
Configuration Client | V3 | 2010.07
Remote connection
Figure 25.2
Bosch Video Management System remote connection to a Bosch Allegiant matrix switch
25.2.2
Configuring the control channel
Perform the following tasks to configure the control channel:
–
Wiring
–
Installing the software
–
Creating Allegiant configuration file
–
Adding the Allegiant matrix to Bosch Video Management System
–
Configuring user names
Wiring
To configure the control channel between Bosch Video Management System and the Allegiant
matrix, connect one PC through an RS-232 serial port to the Allegiant's console port (use the
specified Bosch cable for connection). This can be the Bosch Video Management System
Central Server, or any other PC on the network.
Installing Allegiant Master Control Software
1.
Stop the Central Server service if running (
Start
>
Control Panel
>
Services
> Right-click
Bosch VMS Central Server
>
Stop
)
2.
Install the Allegiant
Master Control Software
on the Central Server and on the Allegiant PC
(if present).
1
Bosch Video Management System Client workstations
2
Central Server with Master Control Software
3
Network
4
Allegiant PC with Master Control Software
5
RS-232 connection
6
encoder
s
7
Allegiant matrix