Bosch Video Management System
Devices page | en
109
Bosch Sicherheitssysteme GmbH
Configuration Manual
Configuration Client | V3 | 2010.07
Initialization status (%)
Additional information is displayed during initialization. When initialization is complete
(100%), you will also have the opportunity to delete all LUNs again.
Note
: On NetApp storage systems, it can take several hours before LUNs are fully deleted.
During that time, the total capacity of newly created LUNs can be reduced. You can only
create new LUNs with full capacity after the old LUNs have been completely deleted.
RAID-DP (reliability focused)
Only displayed for NetApp DSA-N2B20.
Activate this option if you do not wish to use the specified RAID type RAID-4, but would prefer
to use the more reliable RAID type RAID-DP.
17.23.5
Load Balancing page
Main window >
Devices
> Expand
> Expand
>
>
Load Balancing
tab
Allows you to configure limits for write access. When these values are exceeded, data is not
written to the
iSCSI
device but can be lost. For supported devices (for example by Bosch,
NetApp, or Infortrend) leave the default values unchanged. For another device see the
documentation of this device. Start testing with small values.
Soft limit
Enter a value smaller or equal to the value in
Hard limit
. If the values are not exceeded, data is
written to the iSCSI device without internal reorganization. If they are exceeded but smaller
than the values in
Hard limit
, the data is internally reorganized before writing.
Hard limit
If the values are exceeded, data is lost. Reduce the number of cameras that are recorded on
this iSCSI device.
17.23.6
iqn-Mapper dialog box
Main window >
Devices
> Expand
> Expand
> Right-click
>
Map IQNs
Allows you to start the
IQN
mapping process.
17.23.7
LUNs page
Main window >
Devices
> Expand
> Expand
> Expand
>
Allows you to add, remove, or format
LUNs
.
Add
Click to display the
Add LUN
dialog box.
Remove
Click to remove the selected LUNs. A message box is displayed.
CAUTION!
If you change the number of LUNs, the entire iSCSI system will be reorganized and any videos
saved on the system will be lost.
Therefore, before making changes, check the recordings and back up any important videos on
another iSCSI drive or on the computer's hard drive.