Bosch Video Management System
User Groups page | en
153
Bosch Sicherheitssysteme GmbH
Configuration Manual
Configuration Client | V3 | 2010.07
Close Operator Client
Select the check box to allow closing the Operator Client.
Minimize Operator Client
Select the check box to allow minimizing the Operator Client.
Audio Intercom
Select the check box to allow the user to speak on the loudspeakers of an encoder with audio-
in and audio-out function.
Manual Alarm Recording
Select the check box to allow manual alarm recording.
If you clear this check box, the
Metadata
permissions for all available cameras on the
Camera
Permissions
page are cleared and disabled.
Access VRM Monitor
Select the check box to allow access to the
VRM Monitor
software.
Set reference image
Select the check box to allow updating the
reference image
in the Operator Client.
Set Area Selection for Reference Image
Select the check box to allow selecting the area in the camera image for updating the
reference image in the Operator Client.
Limit access to recorded video to the last n hours.
Select the check box to limit the access to recorded videos.
In the list, enter the number of hours.
24.10
Priorities page
Main window >
User Groups
>
>
Priorities
tab
Allows you to configure the timeout for explicit PTZ locking. You can set the priorities for PTZ
control and the display of incoming alarms.
Control Priorities
Move the appropriate slider to the right to decrease the priority for acquiring
PTZ
controls and
Bosch Allegiant trunk lines. A user with a high priority can lock the PTZ controls or the control
of a trunk line for users with lower priorities. You set the timeout for locking PTZ control on
the
Timeout in min.
field. The default setting is 1 minute.
Automatic Popup Behavior
Move the slider to adjust the priority value of Live
Image window
or Playback Image window.
This value is required for incoming alarms to decide whether this alarm is automatically
displayed in the
Alarm Image window
.
For example: If you move the slider for Live Image window to 50 and for the Playback Display
to 70 and an alarm comes in with a priority of 60, the alarm is only automatically displayed if
the user has Playback Display active. The alarm is not automatically displayed when the user
has Live Display active.
Timeout in min.
Enter the time period in minutes.