Additional UL requirements
1.
Installation
For a complete safe and vault installation connect to ’high security cable’. This
product shall be installed in accordance with The Canadian Electrical Code,
Part 1, Safety Standard for Electrical Installations.
2.
Programming - Sensitivity
•
Remote input (terminal 7) must not be able to be activated manually. It
has to be assured that remote input is only active while functional noise
requires its activation.
•
Remote input must not be activated permanently and is limited to
60 seconds.
2.1.
Sensitivity settings verified by UL for Monolithic Concrete:
Minimum
thickness
Maximum
spacing
Mode and
operating radius
Shock
sensitivity *
0.6m
1.98ft
2.5m
8.2ft
Concrete 2.5m
High
4.0m
13.2ft
Concrete 4m
High
5.0m
16.5ft
Concrete 5m
High
•
For coverage of surfaces over corners, the recommended spacing is
reduced by 75%.
2.2.
Sensitivity settings verified by UL for Modular Steel Panels:
Minimum
thickness
Maximum
spacing
Mode and
operating radius
Shock
Sensitivity*
0.006m
0.25in
1.0m
3.3ft
Steel
1m
Low
1.5m
4.9ft
Steel
1.5m
Mid
2.0m
6.6ft
Steel
2m
Mid
•
A detector shall be on each modular wall panel that is not continuously
welded.
•
For coverage of surfaces over corners, the recommended spacing is
reduced by 75%.
2.3.
Sensitivity settings verified by UL for Steel Safes:
Placement
Minimum
thickness
Maximum
spacing
Mode and
operating
radius
Shock
sensitivity*
Body
0.006m
0.25in
1.0m
3.3ft
Steel
1m
Low
Door
Body
0.006m
0.25in
1.5m
4.9ft
Steel
1.5m
Mid
Door
Body
0.006m
0.25in
2.0m
6.6ft
Steel
2m
Mid
Door
•
At least one detector is to be mounted on the door and at least one
detector is to be mounted on the body.
* Note: Shock sensitivity is defined as the sensitivity to single impacts on the
detector or its base. Only in USER MODE, the shock sensitivity can be set
independently of Mode and Operating radius with the help of the ISN-SMS-W7
SensTool Software. If one of the fixed DIP setting is used, the shock sensitivity
corresponds to Mode and Operating radius as indicated in the tables above.
Requisiti supplementari dell'IMQ
Omologazione IMQ CA12.00766
1.
Specifiche tecniche
Livello di prestazione
II° livello
Temperatura di funzionato
+5 ºC fino a +40 ºC
Grado di protezione
IP30
l’assorbimento di corrente
4 mA
immunità ai campi elettromagnetici10V/m−0.08
2 GHz
Accessori non sono coperti dalla certificazione:
•
set da incasso
ISN-GMX-W0
•
scatola da pavimento
ISN-GMX-B0
•
Emisor de ensayo
ISN-GMX-S1
2.
Accessori
Disposizione di prova ISN-GMX-S1
I° livello
Piastra copritoppa GMXP3 GMXP3Z
I° livello
Exigences supplémentaires de NF&A2P
1.
Fixation
Toutes les exigences relatives aux agréments nationaux et concernant
l'application du produit doivent être satisfaites.
2.
Câblage du détecteur
Le câblage peut être réalisé avec du câble souple de 0,22mm ou du câble de
type SYT.
3.
Accessoires
ISN-GMX-D7Feuille anti-perçage
Cette option n'est pas disponible en France.
ISN-GMX-W0 Jeu pour encastrement mural avec couvercle
mode de protection selon (EN 60529)
IP51
capabilité max. de porter du couvercle
25 kg
ISN-GMX-B0 Boite de sol
mode de protection selon (EN 60529)
IP51
capabilité max. de porter du couvercle
1000 kg
4.
Caractéristiques techniques
Tension d'alim: 8,0 Vcc ....... 16 Vcc; ondulation résidu..: 0,25 Vac
Bande de fréquences :……………………………..…..13 à 19 KHz
protection du boîtier (EN 60529, EN 50102) ……………IP43, IK07
5.
Certificat NF&A2P 3 boucliers N° 2730000350A0
Référentiel NF324-H58
ISN-SM-50
273035-00
ISN-GMX-S1
302302-02
ISN-GMX-P0
302302-03
ISN-GMX-W0
302302-08
ISN-GMX-B0
302302-09
ISN-SMS-W7
273034-06
6.
Organisme certificateur :
CNPP Cert.: www.cnpp.com
AFNOR Certification: www.afnor.org
Zusätzliche Anforderungen von VdS
1.
Anwendung
1.
Das Gerät eignet sich zum Einsatz in Einbruchmeldeanlagen nach
DIN EN 50131-1.
2.
Die Einstellposition „Digitaler Filter“ in der Betriebssoftware SensTool
darf nicht verändert werden. Werkseinstellung: OFF
2.
Programmierung
Wird der Steuereingang Klemme 7 “Remote“ zur Empfindlichkeitsreduktion
benutzt, so muss die Übereinstimmung mit den einschlägigen VdS-Vorschriften
im Systemzusammenhang geprüft, bzw. vom VdS akzeptiert werden.
Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, NY 14450
USA
Bosch Sicherheitssysteme GmbH
Robert-Bosch-Ring 5
85630 Grasbrunn
Germany