Inspection and maintenance
Gaz 6000 W – 6720866247 (2019/07)
38
15.3
Checklist for inspection and maintenance
Table 24
Date
1
Call up the last fault saved in the electronics, service
function 1.6A (
2
Check the filter in the cold water pipe (
page 35).
3
Check the flue system visually.
4
Check the gas supply pressure
(
page 31).
mbar
5
Leak test on the gas and water side (
section 5, from
6
Check the heat block (
page 36).
7
Check the burner (
page 36).
8
Check the electrodes (
page 36).
9
Check the pre-charge pressure of the
expansion vessel for the static head of the
heating system.
bar
10
Check the charge pressure of the heating
system.
bar
11
Check the electrical wiring for damage.
12
Check the heating controller settings.
13
Check the set service functions.
Содержание Gaz 6000 W