Flue gas routing
Gaz 6000 W – 6720866247 (2019/07)
12
4.3
Selecting the fan stage
The devices are matched to the flue length by setting the fan stages.
▶ Select the fan stage according to the type of flue gas routing,
appliance type and flue length (
▶ Set the fan stage with the service function 2.bd (
chapter 11,
page 26).
4.3.1
B
22
horizontal flue gas routing
NOTICE:
Poor combustion if restrictor is not installed.
▶ If B
22
flue gas routing is used and appliance output < 35 kW, install
restrictor (accessory 7 736 995 123).
▶ If B
22
vertical flue gas routing is used and appliance output = 35 kW,
install restrictor (accessory 7 736 900 818).
Fig. 4
B
22
horizontal flue gas routing
The 90° elbow on the device is taken into account in the maximum
lengths.
• Each additional 90° elbow is equivalent to 2 m.
• Each additional 45° elbow is equivalent to 1 m.
Table 7 B
22
horizontal flue gas routing
4.3.2
B
22
vertical flue gas routing
Fig. 5
B
22
vertical flue gas routing
NOTICE:
Poor combustion if restrictor is not installed.
▶ If B
22
flue gas routing is used and appliance output < 35 kW, install
restrictor (accessory 7 736 995 123).
▶ If B
22
vertical flue gas routing is used and appliance output = 35 kW,
install restrictor (accessory 7 736 900 818).
• Each additional 90° elbow is equivalent to 2 m.
• Each additional 45° elbow is equivalent to 1 m.
Table 8 B
22
vertical flue gas routing
L [m]
Fan stage
WBN 6000-24
≤ 2
14
2 – 5
16
5 – 9
18
9 – 12
19
12 – 15
20
WBN 6000-28
≤ 2
3
2 – 5
16
5 – 9
17
9 – 15
20
L
0 010 005 934-001
WBN 6000-35
≤ 2
5
2 – 5
6
5 – 9
7
9 – 12
8
L [m]
Fan stage
WBN 6000-24
≤ 2
16
2 – 5
18
5 – 9
19
9 – 15
20
WBN 6000-28
≤ 2
4
2 – 5
14
5 – 9
17
9 – 15
20
WBN 6000-35
≤ 2
8
2 – 5
12
5 – 9
14
9 – 12
18
L [m]
Fan stage
L
0 010 005 933-001