background image

FlexiDome IP

NWD-455VO3-10P | NWD-455V04-10P | PNWD-455V03-20P | 
NWD-455V04-20P 

en

Operating Instructions

Содержание FlexiDome IP NWD-455V04-10P

Страница 1: ...FlexiDome IP NWD 455VO3 10P NWD 455V04 10P PNWD 455V03 20P NWD 455V04 20P en Operating Instructions ...

Страница 2: ......

Страница 3: ...aming 18 1 4 6 Recording 18 1 4 7 Multicast 19 1 4 8 Encryption 19 1 4 9 Configuration 19 1 4 10 Tampering recognition and motion detectors 19 1 4 11 Snapshots 19 1 4 12 Backup 19 1 4 13 Intelligent Video Motion Detection 20 2 Disassembly 21 3 Mounting the unit 22 3 1 Attach the mounting plate 23 3 2 Make the connections 23 3 2 1 Power connection 24 3 2 2 Network and PoE connection 24 3 3 Mount th...

Страница 4: ...snapshots 33 6 1 5 Recording video sequences 33 6 1 6 Running recording program 34 6 2 Recordings page 35 6 2 1 Selecting recordings 35 6 2 2 Controlling playback 36 7 Configuration via the browser 39 7 1 Settings 39 7 2 General Settings 41 7 2 1 Camera identification 41 7 2 2 Password protection 41 7 2 3 Language selection 43 7 2 4 Date and time 43 7 2 5 Time server 43 7 3 Display Settings 45 7 3...

Страница 5: ...nitiator extension 60 7 7 9 Decoupling the drive used 60 7 7 10 Storage information 60 7 8 Partitioning 61 7 8 1 Creating a partition 61 7 8 2 Partition status 63 7 8 3 Editing a partition 63 7 8 4 Deleting partitions 66 7 9 Recording profile 66 7 10 Recording scheduler 69 7 10 1 Activating recording 70 7 10 2 Recording status 71 7 11 Alarm Settings 71 7 11 1 Alarm connections 71 7 12 VCA 74 7 12 ...

Страница 6: ...n 88 7 14 6 Licenses 90 7 14 7 Maintenance 91 7 15 Function test 93 8 Connections between video servers 94 8 0 1 Installation 94 8 0 2 Establishing the connection 94 8 0 3 Connect on alarm 94 8 0 4 Connecting with a Web browser 95 8 0 5 Closing the connection 95 9 Operation with decoder software 96 10 Maintenance 97 10 1 Testing the network connection 97 10 2 Repairs 97 10 2 1 Transfer and disposa...

Страница 7: ...FlexiDome IP en 7 Bosch Security Systems Operating Instructions V 1 0 2006 12 13 Glossary 103 ...

Страница 8: ...llation or in any area classified as a wet location To reduce the risk of fire or electrical shock do not expose this unit to rain or moisture 4 Object and liquid entry Never push objects of any kind into this unit through openings as they may touch danger ous voltage points or short out parts that could result in a fire or electrical shock Never spill liquid of any kind on the unit Do not place o...

Страница 9: ...se fire or shock For 24 VAC units voltage applied to the unit s power input should not exceed 28 VAC User supplied wiring must comply with local electrical codes Class 2 power levels Do not ground the supply at the termi nals or at the unit s power supply terminals If unsure of the type of power supply to use contact your dealer or local power company 9 Servicing Do not attempt to service this uni...

Страница 10: ...stitutions may cause fire electrical shock or other hazards 12 Safety check Safety checks should be performed upon completion of service or repairs to the unit to ensure proper operating condition 13 Installation Install in accordance with the manufacturer s instructions and in accordance with applicable local codes 14 Attachments changes or modifications Only use attach ments accessories specifie...

Страница 11: ...jury or death WARNING Medium risk Indicates a potentially hazardous situation If not avoided this could result in serious bodily injury or death CAUTION Indicates a potentially hazardous situation If not avoided this may result in minor or moderate injury Alerts the user to important instructions accompanying the unit i NOTICE This symbol indicates information or a company policy that relates dire...

Страница 12: ...ection 810 of the National Electrical Code ANSI NFPA No 70 provides information regarding proper grounding of the mount and supporting structure grounding of the coax to a discharge unit size of grounding conductors location of discharge unit connection to grounding electrodes and requirements for the grounding electrode Permanently connected equipment Incorporate a readily accessible disconnect d...

Страница 13: ...ning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures reorient or relocate the receiving antenna increase the separation between the equipment and receiver connect the equipment into an outlet on a circuit dif ferent from that to which the receiver is connected consult the dealer or an experienced radio TV techni cian for h...

Страница 14: ...oschsecuritysystems com Disposal Your Bosch product was developed and manufactured with high quality material and components that can be recycled and reused This symbol means that electronic and electrical appli ances which have reached the end of their working life must be collected and disposed of separately from household waste material Separate collecting systems are usually in place for disus...

Страница 15: ...a is easy to install and ready to use and offers the best solution for demanding scene conditions Fea tures include Impact resistant dome Tamper resistant housing Intelligent Video Motion Detection iso enhanced Video and data transmission over IP data networks Tri Streaming function for simultaneous encoding with three individually definable profiles Multicast function for simultaneous picture tra...

Страница 16: ...ger MPEG ActiveX control DirextX control Microsoft Internet Explorer Sun JVM Player and archive player Adobe Acrobat Reader Type number NWD 455V03 10P NWD 455V04 10P NWD 455V03 20P NWD 495V04 20P Lens Varifocal 2 6 to 6 mm F1 4 Varifocal 3 7 to 12 mm F1 6 Varifocal 2 6 to 6 mm F1 4 Varifocal 3 7 to 12 mm F1 6 Standard PAL NTSC Supply volt age 24 VAC 50 Hz or 12 VDC use class 2 power supply or PoE ...

Страница 17: ...ystem 128 MB video memory 1024x768 display with 24 bit color Network interface 100 BaseT DirectX 9 0b 1 4 Overview of functions The integrated camera unit incorporates a network video server Its primary function is to encode video and control data for transmission over an IP network With its MPEG 4 encoding it is bandwidth efficient for both network and recording The use of existing networks means...

Страница 18: ...for example VIP XD can be used as a receiver Computers with decoding software such as VIDOS or computers with the Microsoft Internet Explorer web browser installed can also be used as receivers 1 4 4 Video encoding The camera uses the MPEG 4 compression standard Thanks to efficient encoding the data rate remains low even with high image quality and can also be adapted to local conditions within wi...

Страница 19: ...also pos sible Configuration settings can be stored as files on a com puter and copied from one camera to another 1 4 10 Tampering recognition and motion detectors The camera offers a wide range of configuration options for alarm signaling in the event of tampering with the camera An algorithm for detecting movement in the video image is also part of the scope of delivery and can optionally be ext...

Страница 20: ...2 Operating Instructions Bosch Security Systems 1 4 13 Intelligent Video Motion Detection The intelligent video motion detection iVMD system of the camera uses advanced analysis algorithms with comprehensive functions for the detection of motion ...

Страница 21: ...move the trim ring with dome by pulling it off of the base 3 Remove the inner liner by pulling it off of the base 4 Loosen the three Phillips captive screws until the mount ing plate separates from the body Mounting plate Camera module and mounting base Inner liner Trim ring and dome CAUTION Installation should only be performed by qualified service personnel in accordance with the National Electr...

Страница 22: ...n of the screw holes and the entry hole for the wires Fig 3 1 Surface mounting side connection Fig 3 2 Surface mounting top connection Wires Mounting plate Conduit Integrated camera unit and base Three screws M5 supplied Three screws supplied with camera Solid surface three pre drilled 8mm holes Suspension wire Cap Mounting plate Conduit Three screws supplied with camera Integrated camera unit and...

Страница 23: ...overing the side entrance b attach a 22 mm inch PG16 gland conduit to the mounting plate 3 2 Make the connections To connect the wiring to the camera use the metal mounting wire to hold the camera during installation on a ceiling Make the power and network connection from inside the connection box Fig 3 3 Preparation 1 Pull out the connection box from the camera encasing 2 To open the connection b...

Страница 24: ...or in the connec tion box 3 2 2 Network and PoE connection 1 Use a shielded UTP Category 5 cable NOTICE Power can be supplied to the camera via the Ethernet cable compliant with the Power over Ethernet IEEE 802 3af standard 2 Crimp a RJ45 connector onto the cable 3 Connect the network cable to the network connector in the connection box 3 3 Mount the camera 1 Close and screw on the cover of the co...

Страница 25: ...e physical default position of the camera is that the top of the image corresponds to the indication TOP The camera module position can be adjusted along three axes When adjusting the camera position ensure that the picture dis play on the monitor is level Set the camera to the desired posi tion by performing the following steps For horizontal adjustment pan rotate the camera module in the base Do...

Страница 26: ...e monitor by loosening the focus screw and turning the mechanism until the image is in focus 3 Readjust the focal length if necessary 4 Repeat these two adjustments until the desired view is in focus 5 Tighten both screws 6 Remove the adjustment cap from the lens 4 3 Basic settings The camera normally provides an optimal picture without the need for further adjustments The camera has an Installer ...

Страница 27: ...camera in your network a network valid IP address must be assigned The IP address can also be set remotely via the Configuration Manager This SW package is supplied with the camera on the CD The factory default IP address is 192 168 0 1 Table 4 2 IP address submenu Up key Menu select key Right key Down key Left key Function Selection Description Network Select sub menu Select to set the network IP...

Страница 28: ...ce the dome onto the base and rotate until it clips into place If necessary clean its surface with a soft cloth 4 Place the sealing ring and the trim ring over the dome 5 Align the tamper resistant screws in the trim ring with the threaded ends in the mounting base 6 Use the supplied special screwdriver bit to tighten the three tamper resistant screws i NOTICE The new IP address subnet mask and ga...

Страница 29: ...n 1024 768 pixels 16 or 32 bit color depth Intranet or Internet network access To play back live video images an appropriate MPEG ActiveX must be installed on the computer If necessary the required software and controls can be installed from the product CD provided a Insert the CD into the CD ROM drive of the computer If the CD does not start automatically open the root directory of the CD in Wind...

Страница 30: ...the connection is established the Live page with the video image appears In the application title bar the Livepage selection is used to operate the camera the Set tings selection is used to configure the camera and the applica tion interface i NOTICE A camera offers you the option of limiting access across various authorization levels i NOTICE If the connection is not established the maximum numbe...

Страница 31: ...is used for network access control 802 1x authentication the camera must be configured first To config ure the camera for a Radius network connect it directly to a PC via a crossed network cable and configure the two parameters identity and password Only after these have been configured can you communicate with the camera via the network ...

Страница 32: ...tion various text overlays may be visible on the live video image Other information may also be shown next to the live video image on the Livepage The display depends on the settings on the Livepage configuration page 6 1 1 Processor load When accessing the camera with a browser the processor load is displayed in the upper right of the window next to the Bosch logo Move the mouse cursor over the i...

Страница 33: ... of alarms are shown in the Event log field These messages can be saved automatically in a file 6 1 4 Saving snapshots Individual images from the video sequence that is currently being shown on the Livepage can be saved in JPEG format on the computer s hard drive 1 Click the camera icon to save single images 2 The image is saved at a resolution of 704 576 480 pixels 4CIF The storage location depen...

Страница 34: ...tart the installation 2 Select a language from the list box at the top 3 Click Tools in the menu 4 Click Archive Player the installation starts 5 Follow the instructions in the installation program The Archive Player is installed together with the Player 6 After a successful installation two new icons for the Player and the Archive Player appear on the desktop 7 Double click the Player icon to sta...

Страница 35: ...n bar in the upper section of the window The playback page appears 6 2 1 Selecting recordings In the left section of the page first select the partition whose recordings you want to view All sequences that are saved in the partition are displayed in the list A running number track is assigned to each sequence Start time and stop time recording duration number of alarms and recording type are displ...

Страница 36: ...me interval displayed by moving the blue area to the left or right while holding down the mouse button You can change the time interval displayed by clicking the plus or minus icons The display can span a range from two months to a few seconds You can select a different sequence for playback by click ing on the corresponding blue marking If required drag the green arrow to the point in time at whi...

Страница 37: ...forward or rewind speed changes depending on how far you move the slide control toward the runner icons You can continuously select playback speed by means of the speed regulator Red bars within the blue gray sequence fields indicate the points in time where alarms were triggered Drag the green arrow to navigate to these points quickly In addition you can set markers in the sequences so called boo...

Страница 38: ...exiDome IP V 1 0 2006 12 Operating Instructions Bosch Security Systems i NOTICE Bookmarks are only valid while you are in the Recordings page they are not saved with the sequences As soon as you leave the page all bookmarks are deleted ...

Страница 39: ...w page contain ing the configuration menu is opened All settings are stored in the camera memory and they are pre served even if the power is interrupted Configuration menu tree The configuration menu tree allows all parameters of the cam era to be configured The configuration menu is recommended for expert users or system administrators All unit parameters can be accessed in this mode Changes tha...

Страница 40: ...responding page is opened The settings are changed by entering new values or by selecting a pre defined value in a list field Saving changes After making changes in a window click the Set button to send the new settings to the unit and save them there Click on the Settings link at the top of the window to close the window without saving the changes made i NOTICE Save the changes made in each windo...

Страница 41: ...ensive systems for example using the VIDOS or BVMS software Camera ID Each camera should be assigned a unique identifier that can be entered here as an additional means of identification 7 2 2 Password protection A camera is generally protected by a password to prevent unau thorized access to the unit You can use various authorization levels User name to limit access i NOTICE The camera name is us...

Страница 42: ...iew the live video image and switch between the different live image displays Password You can define and change a separate password for each user name if you are logged on as Service or if the unit is not pro tected by a password Enter the password for the selected user name here Confirm password Re enter the new password to rule out typing mistakes i NOTICE Proper password protection is only gua...

Страница 43: ...rtant to synchronize their internal clocks For example it is only possible to carry out correct identification and evaluation of recordings occurring at the same time if all devices are operating on the same time 1 Enter the current date Since the unit time is controlled by the internal clock it is not necessary to enter the day of the week This is added automatically 2 Enter the current time or c...

Страница 44: ...elect the appropriate time zone for the system 1 Click Set 2 Click Details A new window opens showing an empty table 3 Click Generate to fill the table with the preset values from the camera 4 Select the region or the city which is closest to the sys tem s location from the list box below the table 5 Click one of the entries in the table to make changes The entry is highlighted 6 Clicking Delete r...

Страница 45: ...sets the position of the camera name overlay It can be displayed at the Top at the Bottom or at a position of your choice using the Custom option Or it can be set to Off if no overlay of this information is to be shown Time stamping This field sets the position of the time and date overlay It can be displayed at the Top at the Bottom or at a position of your choice which you have pre defined using...

Страница 46: ... are marked with a small green rectangle A red rectangle indicates that the sequence live or saved has been manipulated 7 4 Encoder Settings For encoding the video signal you can select two profiles and change the presets for the profiles 7 4 1 Selecting an encoder profile You can adapt the MPEG 4 data transmission to the operating environment for example network structure bandwidth data structure...

Страница 47: ...nels resolution 352 288 240 pixels Profile 6 ISDN 1B For ISDN connections via one B channel resolution 352 288 240 pixels Profile 7 Modem For analog modem connections at 20 kBit s resolution 352 288 240 pixels Profile 8 GSM For GSM connections at 9 600 baud resolution 176 144 120 pixels Active profile Here you can select the desired profile for each of the two streams You will see a preview for ea...

Страница 48: ... switch between profiles by clicking the asso ciated tabs i NOTICE Stream 2 is always transmitted for alarm connections and automatic connections Take this into account when assigning the profile i NOTICE The profiles are rather complex They include a number of parameters that interact with one another Therefore it is generally best to use the default profiles The profiles should only be changed i...

Страница 49: ...he Max data rate field Encoding interval The figure selected here determines the interval at which images are encoded and transmitted For example entering 4 means that only every fourth image is encoded the following three images are skipped this can be particularly advanta geous with low bandwidths The image rate in IPS Images Per Second is displayed next to the text block Video resolution Here y...

Страница 50: ...p between movement and image definition focus Selecting Manual allows you to set a value between 4 and 31 on a slide bar The value 4 represents the best quality with if necessary a lower frame refresh rate depending on the settings for the max imum data rate A value of 31 results in a very high refresh rate and lower image quality I frame video quality This setting allows you to adjust the image q...

Страница 51: ...ndividual images which are transmitted Overwrite The same file name is always used and any existing file will be overwritten with the current file Increment A number from 000 to 255 is added to the file name and automatically increased by 1 When it reaches 255 it starts again from 000 Date time suffix The date and time are automatically added to the file name When setting this parameter please ens...

Страница 52: ...password that gives you access to the FTP server Path on FTP server Enter the exact path on which you wish to post the images on the FTP server Post JPEG from camera Check the box to activate one or more camera inputs for the JPEG image An enabled camera input is indicated by a check mark 7 5 Camera settings i NOTICE The numbering follows the labeling of the video inputs on the actual unit i NOTIC...

Страница 53: ... 60 1 50 1 100 1 120 1 250 1 500 1 1000 1 2000 1 5000 1 10K as long as the light level of the scene permits FL flickerless mode avoids interference from light sources Gain When the Gain mode is On the camera automatically sets the gain to the lowest possible value needed to maintain a good picture NightSense Nightsense extends the low light performance of the camera In AUTO mode the camera automat...

Страница 54: ...of the image Parts outside this area may be underexposed or overex posed this is normal Auto Black Autoblack ON automatically increases the visibility of details i NOTICE If NightSense is active some noise or spots may appear in the picture This is normal camera behavior NightSense may cause some motion blur on moving objects If the camera is in monochrome mode all color related menu items are dis...

Страница 55: ...he camera to constantly adjust for optimal color reproduction AWB HOLD Puts the ATW on hold and saves the color set tings Red Gain Offset factory white point alignment reducing red introduces more cyan Blue Gain Offset factory white point alignment reducing blue introduces more yellow i NOTICE It is only necessary to change the white point offset for special scene conditions ...

Страница 56: ...r the camera to optimize the picture after a mode reset 7 6 Recording You can record the images from the camera in the RAM memory of the unit or in an appropriately configured iSCSI storage device Local RAM memory is suitable for short term recordings and pre alarm recordings in Ring mode operation For long term authoritative images it is essential that you use appropri ately sized iSCSI storage I...

Страница 57: ... of these settings 1 Click Log to view a status report with logged actions A new window opens 2 In this window click Delete to delete all entries Entries are deleted immediately you cannot undo this process 3 Click Close to close the window i NOTICE If you select VRM the Video Recording Manager manages all recording and you are not able to make any further configurations via the web browser NOTICE...

Страница 58: ...set the configuration parameters 7 7 1 iSCSI IP address 1 Enter the IP address of the required iSCSI server here 2 Click Connect The connection to the IP address is estab lished The iSCSI LUN map field contains the correspond ing logical drives i NOTICE The storage device selected must adhere to the iSCSI specification be available on the network and be completely set up Amongst other things it mu...

Страница 59: ...a attempts to create a connection to the required drive using this data As soon as a connection has been established the selected drive is used for recordings 7 7 3 Target IP address Enter the IP address of the required iSCSI server here 7 7 4 Target node Enter the number of the iSCSI server target node 7 7 5 Target LUN Enter the LUN of the required drive 7 7 6 Target password If the drive is pass...

Страница 60: ...g used by another person you can decouple the drive and connect the drive with the camera 1 Double click a drive that is already being used in the LUN map You will see a warning message 2 Confirm the decoupling of the current user The drive is released and can be connected to the camera 7 7 10 Storage information The status of the currently selected storage medium and the data throughput are displ...

Страница 61: ...fied for the partition Modifying these parameters leads to reorganiza tion during which stored data is lost In addition the page pro vides you with an overview of the drive data for example total memory A pie chart indicates how much memory space is parti tioned for recordings 7 8 1 Creating a partition Creating a new partition is performed using separate windows in which information is presented ...

Страница 62: ...he window to con tinue with the next step 5 Click Back in the lower section of the window to view the previous step again 6 Click Cancel to cancel the process and close the wizard Saving changes After you have made all necessary settings you must transfer the settings to the unit and save them To do this you need to quit the help in the last window using the Finish button 1 Switch to the last wind...

Страница 63: ...atus A window opens showing information on the high lighted partition This window provides information about the current configuration of the partition No changes can be made here 2 Click OK to close the window 7 8 3 Editing a partition CAUTION Changes to a partition lead to a re organization which results in the loss of all sequences stored on that partition Consequently you should back up all im...

Страница 64: ... 4 After closing the window click Set in the main window to transfer the changes to the unit and to save them Type of recording Select the required recording type In Ring mode the recording proceeds continuously When the maximum hard drive space is reached the oldest recordings are automatically overwritten In Linear mode the recording proceeds until the entire hard drive space is full The recordi...

Страница 65: ...can be recorded in each alarm track Accord ingly the number of alarms entered can be recorded and archived A partition can contain a maximum of 128 alarm recordings If the Ring mode is set for a partition the latest alarm recordings are always saved in the preset number If the Linear mode is selected the recording is stopped as soon as the total number of alarm tracks has been recorded Alarm track...

Страница 66: ... 2 Click Set to transfer the changes to the unit and to save them 7 9 Recording profile You can define up to ten separate recording profiles You then assign these to individual days or times of day in the recording scheduler Modify the names of the recording profiles on the tabs in the Recording planner page CAUTION Deleting a partition leads to the entire hard drive being reorganized and loss of ...

Страница 67: ... you want to copy the currently visi ble settings to another profile A dialog appears and you can select the target profile for the copied settings 4 Click Set in each profile tab that you want saved Standard profile Select the encoder profile to use for continual recording Encoder Select which data stream to record here i NOTICE The recording profile can deviate from the standard setting Active p...

Страница 68: ...the checkbox to activate alarm track recording The pre alarm time gap is displayed automatically Post alarm time Select the post alarm time gap from the list box Post alarm profile Select the encoder profile to use for recording during the post alarm time The Standard profile option sets this to the same as the standard profile Motion detection video alarm Select the alarm type that is to trigger ...

Страница 69: ...ods in 15 minute intervals for any day of the week When you move the mouse cursor over the table the time is displayed In addition to weekdays you can also define holidays which over ride the settings for that weekday This allows you to apply the settings for Sundays to other days of the week 1 Click a profile 2 Click a field in the table and holding down the left mouse button drag the cursor acro...

Страница 70: ...tion s The window closes 5 Assign the defined holidays to the recording profile as described above Delete holidays You can delete user defined holidays at any time 1 Click Delete in the Holidays tab This opens a new win dow 2 Click the date to be deleted 3 Click OK The selection is removed from the table and the window closed 4 Repeat for any other dates to be deleted Profile names You can change ...

Страница 71: ...ons You can select the response of the camera when an alarm occurs In case of an alarm the camera can automatically estab lish a connection to a predefined IP address compatible MPEG 4 compatible hardware receiver or computer with recep tion software You can enter up to ten IP addresses which will be selected in order by the unit in case of an alarm until a con nection is established Connect on al...

Страница 72: ...ontrolling system such as VIDOS or BVMS The camera connects to all devices protected by the same general password To define a general password 1 Select 10 in the Number of Destination IP address list box 2 Enter 0 0 0 0 in the Destination IP address field 3 Enter the password in the Destination password field 4 Set the user password of all the devices to be connected to this password Setting desti...

Страница 73: ...re and activate encryption for media data video audio metadata on the Encryption page see Encryption on page 86 Auto connect Select On if an active connection should be re established auto matically to one of the previously specified IP addresses after each restart connection breakdown or network failure i NOTICE Stream 2 is always transmitted for automatic connections This should be taken into ac...

Страница 74: ... can configure the video content analysis for the cam era If necessary click Default to return all settings to their default values 7 12 1 Analysis Select the option On to activate the video content analysis As soon as the VCA is activated metadata are created Depend ing on the analysis type selected and the relevant configuration additional information overlays the video image in the small window...

Страница 75: ...han zero 7 12 4 Sensitivity Sensitivity is available for the Motion analysis type The basic sensitivity of the motion detector can be adjusted for the envi ronmental conditions to which the camera is subject The sen sor reacts to variations in the brightness of the video image i NOTICE On the Livepage configuration page you can enable additional information overlays for the live video image too se...

Страница 76: ...arms manipulation of the orientation or location of a camera resulting from turning the camera mounting bracket for instance Selecting the area The areas of the image to be monitored by the motion detector can be selected The video image is subdivided into 858 square sensor fields You can activate or deactivate each of these fields individually If you wish to exclude particular regions of the came...

Страница 77: ... be selected Trigger delay You can set delayed alarm triggering The alarm is only triggered after a set time interval in seconds has elapsed and then only if the triggering condition still exists If the original condition has been restored before this time interval elapses the alarm is not triggered This allows you to avoid false alarms triggered by short term changes for example cleaning activiti...

Страница 78: ...rned 1 Click Reference to save the currently visible video image as a reference 2 Click Select area and select the areas in the reference image that are to be monitored 3 Check the box Reference check to activate the on going check The stored reference image is displayed in black and white below the current video image and the selected areas are marked in red Selecting the area You can select the ...

Страница 79: ...ative to automatic connecting alarm states can also be documented by e mail In this way it is possible to notify a recipient who does not have a video receiver In this case the camera automatically sends an e mail to a user defined e mail address 7 13 1 Send alarm e mail Select On if you want the unit to automatically send an alarm e mail in the event of an alarm 7 13 2 Mail server IP address Ente...

Страница 80: ...he maximum address length is 49 characters 7 13 5 Sender name Enter a unique name for the e mail sender for example the location of the unit This makes it easier to identify the origin of the e mail 7 13 6 Send e mail for testing Test the e mail function by clicking Send now An alarm e mail is immediately created and sent i NOTICE When a cellphone is used as the receiver make sure to activate the ...

Страница 81: ... the unit into an existing network Click Set after entering a new IP address To do this enter the old IP address followed by reset for instance 192 168 0 80 reset in the address bar of your web browser When the camera is i NOTICE Changes to the IP address subnet mask or gateway address are transferred to the unit by clicking Set However they do not become active until the device is restarted ...

Страница 82: ... use in a local net work choose UDP HTTP browser port Select a different HTTP browser port from the list if required The default HTTP port is 80 To limit connection to HTTPS you must deactivate the HTTP port To do this activate the Off option HTTPS browser port To limit browser access to encrypted connections choose an HTTPS port from the list The standard HTTPS port is 443 By activating the Off o...

Страница 83: ...ctivate telnet support making telnet connections impossible Ethernet link type If the camera is connected to the network via a switch both devices must have the same preset network connection type If necessary ask your network administrator what value the asso ciated switch is set to Choose Auto for an autosensing network connection If neces sary you can set the value to 10 or 100 MBit s for eithe...

Страница 84: ...ate with the device 1 Enter the user name that the Radius server uses for the camera in the identity field 2 Enter the password that the Radius server expects from the camera The Radius server must also be appropriately configured Automatic IP assignment If the network has a DHCP server for dynamic IP allocation you can activate DHCP here In this case the IP entered above on this page is overwritt...

Страница 85: ... 0 0 to 239 255 255 255 The multicast address can be the same for multiple streams However it is then necessary to use a different port in each case so that multiple data streams are not sent simultaneously using the same port and multicast address Multicast address video 1 Enter a valid multicast address for each stream to be operated in multicast mode duplication of the data streams in the net w...

Страница 86: ...media data video audio metadata here Activation also causes RCP connections to be encrypted To encrypt data streams you should only allow browser connections via SSL To do this you must deactivate all ports and protocols except HTTPS see HTTPS browser port on page 82 You can select individual data streams for encryption When a key is generated for a stream data is encrypted If you delete the key d...

Страница 87: ...manually Automatic key exchange Mark this checkbox to activate an automatic key exchange between two devices or the camera and a software decoder across an encrypted connection 7 14 4 Version information This window is for information only and cannot be modified Keep this information at hand when seeking technical support For example you can copy the hardware and firmware version numbers to paste ...

Страница 88: ...n window and the upper area of the window banners For access via the Internet Intranet there must be a connection in order to display the image The image files are not stored on the camera 1 Mark the check boxes for the information to be displayed on the Livepage The selected elements are checked 2 Check on the Livepage whether and how the desired items are displayed i NOTICE Either GIF or JPEG im...

Страница 89: ...able image on the local network Show alarm input Alarm inputs are displayed next to the video image as icons along with their assigned names If an alarm is active the corre sponding icon changes color Show VCA metadata When video content analysis VCA is activated additional infor mation is displayed in the live video stream For example in Motion mode the sensor areas for motion detection are marke...

Страница 90: ...Select this option to save system messages in a text file on the local computer This file can be viewed edited and printed with any text editor or the standard Office software File for event log Enter the path for saving the event log here If necessary click Search to find a suitable folder File for system log Enter the path for saving the system log here If necessary click Search to find a suitab...

Страница 91: ...he unit on site The latest firmware can be obtained from your customer service center or from the Bosch Security Systems download area i NOTICE The activation key cannot be deactivated again and is not transferable to other units CAUTION Before starting the firmware update make sure that you have selected the correct upload file Uploading the wrong files can result in the unit no longer being addr...

Страница 92: ... the upload has failed and must be repeated To perform the upload you must switch to a special page 1 In the address bar of your browser after the unit IP address enter main htm for example 192 168 0 80 main htm 2 Repeat the upload Configuration download You can save configuration data for the camera to a computer and load saved configuration data from a computer to the unit 1 Click Download a dia...

Страница 93: ...e upload To work with an SSL connection both sides of the connection must have the appropriate certificates You can upload one or more certificate files one at a time to the camera 1 Enter the full path of the file you wish to upload or click Browse to locate the file 2 Click Upload to start the file transfer The unit restarts automatically after a successful upload 7 15 Function test The camera o...

Страница 94: ...em to the power supply 8 0 2 Establishing the connection There are three options for establishing a connection between a transmitter and a compatible receiver in a closed network an alarm a Web browser via the configuration manager 8 0 3 Connect on alarm With the appropriate configuration a connection between a transmitter and a receiver is established automatically when an alarm is triggered Afte...

Страница 95: ...hot of the selected video source is displayed on the page 2 Click an MPEG 4 connection to begin displaying the video images on the connected monitor 8 0 5 Closing the connection The connection may be closed using a Web browser 1 Use the Web browser to connect to the receiver Its home page is displayed 2 In the title bar of the Monitor window on the page Connec tions click on the X icon to end the ...

Страница 96: ...eamless management of digital video audio and data across any IP net work It is designed to work with Bosch CCTV products as part of a total video security management system Now you can inte grate your existing components into one easy to manage sys tem or use Bosch s full line capabilities and benefit from a complete security solution based on cutting edge technology and years of experience DiBos...

Страница 97: ...o the network Check the cable connections in this case The device is not correctly integrated into the network Check the IP address subnet mask and gateway address 10 2 Repairs 10 2 1 Transfer and disposal The camera should only be passed on together with this instal lation guide The unit contains environmentally hazardous mate rials that must be disposed of according to law Defective or superfluo...

Страница 98: ... table is intended to help you identify the causes of malfunctions and correct them where possible Malfunction Possible causes Solution No image transmis sion to remote loca tion Defective camera Connect a local monitor to the camera and check the camera function Faulty cable connections Check all cables plugs contacts and connections No connection estab lished no image transmission The unit s con...

Страница 99: ...mer Service and replace if neces sary Incorrect update file Enter the IP address followed by main htm in your web browser and repeat the upload No LUNs are dis played after connect ing to the iSCSI server iSCSI server configuration has incorrect LUN mapping Check iSCSI server configuration and reconnect LUN FAIL is dis played under a node after connecting to the iSCSI server The LUN list could not...

Страница 100: ...e CCD SNR 50 dB Video output 1 Vpp 75 Ohm Synchronization Internal or Line Lock selectable Shutter AES 1 60 1 50 to 1 15000 flickerless Auto black ON OFF selectable BLC Center window weighting White balance Automatic 2500 9000K AWB hold ALC lens DC iris Power consumption 10 5 VA max Weight 1 8 kg 3 96 lb without lens Operating temperature 10 C to 40 C 14 F to 104 F Controls OSD with softkey operat...

Страница 101: ...sch Security Systems Operating Instructions V 1 0 2006 12 Image refresh rate Field image based coding 1 50 60 fields s adjustable PAL NTSC Network protocols TCP UDP IP HTTP S IGMP v2 v3 ICMP ARP RTP Telnet DHCP SNMP V2 802 1x All versions ...

Страница 102: ...rating Instructions Bosch Security Systems 12 1 Dimensions mm inch 12 2 Accessories Contact your Bosch representative for the latest available accessories 40 37 42 03 1 65 1 59 22 35 1 87 0 88 47 6 0 99 25 22 4 76 121 158 6 2 22 5 0 9 23 5 5 6 0 9 142 5 ...

Страница 103: ...s per second the actual data rate CIF Common Intermediate Format video format with 352 x 288 240 pixels DNS Domain Name Service DHCP Dynamic Host Configuration Protocol allows a network device to receive a dynamically allocated IP address and other network parameters from a server in a network FTP File Transfer Protocol Full duplex Simultaneous data transmission in both directions sending and rece...

Страница 104: ...er rates for example via the Internet Net mask A mask that explains which part of an IP address is the net work address and which part comprises the host address It is usually written in dotted decimal notation with full stops separating the bytes for example 255 255 255 192 NTP Network Time Protocol is a standard for synchronizing the system clocks in computers in packet switching networks NTP us...

Страница 105: ...smission in IP based networks Subnet mask See Net mask TCP Transfer Control Protocol Telnet Login protocol with which users can log on to a remote computer host on the Internet TSL TSL Transport Layer Security versions 1 0 and 1 1 are stan dardized enhancement of the SSL 3 0 protocol see SSL TTL Time To Live life cycle of a data packet in station transfers UDP User Datagram Protocol URL Uniform Re...

Страница 106: ...Bosch Security Systems Robert Koch Straße 100 D 85521 Ottobrunn Germany www boschsecuritysystems com Bosch Security Systems 2007 ...

Отзывы: