D7212GV2 

 

 

 D7212GV2 Release Notes for Version 7.07  

 

F01U009079-04 

Page 8 

© 2007 Bosch Security Systems, Inc. 

3.2.2 

ANSI/SIA CP-01 Compliance 

 

 

Minimum system requirements for  
Classification in accordance with 
ANSI/SIA CP-01-2000: 

 

UL Listed and Classified control unit 
Model D9412GV2, D7412GV2, or 
D7212GV2 

 

UL Listed and Classified keypad Model 
D1256, D1257, D1260, D1255, 
D1255R, or D1255 RW 

 

UL Listed Local Bell

  

 

 

 

For detailed descriptions and settings 
required for SIA CP-01 compliance, refer 
to the 

GV2 Series Program Entry Guide 

Supplement for SIA CP-01 Compliance

 

(P/N: F01U032733). 

Exit Delay Warning 

Prompt: 

A# Exit Warning 

When enabled, the Exit Delay tone at all keypads in 
an area about to arm is replaced by a fast Trouble 
Tone for the last ten seconds. The Alarm Bell output 
also pulses ON and OFF for the last ten seconds of 
the Exit Delay. 

Entry Delay Warning 

Prompt: 

A# Entry Warning 

When enabled, the Alarm Bell output pulses ON and 
OFF for the last ten seconds of the Entry Delay. 

Exit Time Restart 

Prompt: 

A# Exit Restart 

When enabled, this feature causes an area’s Exit Delay 
timer to restart upon re-entry. To consider the area as 
vacated, the control panel must detect a point with a 
delay alarm response changing from normal to off-
normal, and back to normal. When vacated, a fault on 
any point with a delay alarm response during the 
remaining Exit Delay causes the countdown to restart 
from the beginning. 

Exit Error 

If a point with a delay alarm response remains off-
normal when the Exit Delay expires, the Entry Delay 
starts. If the system is not disarmed within the 
programmed time, an Exit Error Alarm is generated. 
This feature is always enabled and has no 
configuration parameters. 

The alarm with an exit error event creates a new 
Modem IIIa2 message that the central station might 
need to add to their automation software. Refer to 
Event 38 in the 

Modem IIIa

2

 Messages

 section of the 

Appendix in the 

ConettixD6600/D6100 Computer 

Interface Manual

 (P/N: 4998122703) for the details of 

central station data changes. 

Recent Closing 

If a point with 

P# Type

 set to 1, 2 or 3 goes into 

alarm within 2 min after the exit delay expires, then 
the alarm event sent is considered a Recent Closing 
Alarm. This feature is always enabled and has no 
configuration parameters. The alarm with recent 
closing event creates new Modem IIIa

2

 messages that 

the central station might need to add to their 
automation software. Refer to Event 27 in the 

Modem 

IIIa

2

 Messages

 section of the Appendix in the 

ConettixD6600/D6100 Computer Interface Manual

 

(P/N: 4998122703) for the details of central station 
data changes. 

Master Arm – No Exit 

Prompt: 

A# Arm No Exit 

When enabled, this feature sets an area’s arming state 
to Perimeter Armed if no perimeter points with 
delayed response are faulted and returned to normal 
in that area during the Exit Delay of a Master Arm 
attempt. This feature applies to CMD 1, Passcode 
arming, Keyswitch and remote master arming. 

Fixed Passcode Length 

Prompt: 

Passcode Length 

When enabled, this feature sets a fixed length to all 
user passcodes. During Entry Delay, the code is 
accepted when the last digit is pressed to disarm the 
area. At any other time, the [Enter] key is required for 
acceptance of the code. 

Содержание D7212GV2

Страница 1: ...07 RADXSKED v1 03 GV2AUX v1 01 Table 2 Supporting Literature for D7212GV2 with Version 7 07 Firmware and Later Document Name Part Number D7212GV2 Program Entry Guide F01U003804 03 D7212GV2 Program Record Sheet F01U003803 03 D7212GV2 Operation and Installation Guide F01U003805 02 D7212GV2 Approved Applications Compliance Guide F01U003806 02 Older revisions have alphabetic revision identifiers for e...

Страница 2: ...nt corrupted data account codes for systems that communicate with BIS 2 0 Security Engine These changes are only compatible with BIS Security Engine v2 1 1271 or later This addresses the issues described in the BIS SEE and GV2 G Series Technical Service Note P N F01U073249 Changes made allow the Relay Latches on point fault option for the P Relay Response Type feature to reset when a passcode is e...

Страница 3: ... is installed on the RPS workstation special software firewall settings might be required to allow outgoing traffic Refer to your firewall software for configuration information Any DX4020 or D9133TTL E used for enhanced communication to a central station receiver or with RPS over a network must be configured to use Datagram Mode 2 when the control panel firmware is version 7 06 and later Refer to...

Страница 4: ...evice are now included when a test report is sent using COMMAND 41 or a sked Corrections enhance the reliability and performance of RPS network connection These corrections also decrease the delay in reporting a break in the Ethernet connection to the control panel s Network Interface Module within the time limits required by UL For UL 1610 Line Security formerly Grade AA Intrusion System installa...

Страница 5: ... panel wide Communications Failure Relay output to activate when events in Route Groups 2 through 4 do not reach the central station Previously this relay output activated only on a communication failure for Route Group 1 2 5 Version 7 02 The Phone Line Supervision feature has improved accuracy in detecting the phone line The Modem IIIa2 product ID is changed to the same ID as the G Series control...

Страница 6: ...ion This feature was updated to manage the control panel clock adjustments over a period of time instead of simply jumping to the new time This enhancement allows consistent execution of Skeds at their intended times When a TimeSync adjustment is in process the Time Date idle text display is modified with a or sign to indicate control panel time is increasing or decreasing to match the target time...

Страница 7: ...ed Fire Bypass Trouble Annunciation The Fire Bypass warning display is modified to generate a Trouble warning tone that can be silenced with COMMAND 4 The trouble condition self clears when all bypassed fire points within the keypad s scope return to service This feature is always on and cannot be disabled Summary Fire Relay Options An option is added that changes the duration of the Panel Wide Su...

Страница 8: ...s the Entry Delay starts If the system is not disarmed within the programmed time an Exit Error Alarm is generated This feature is always enabled and has no configuration parameters The alarm with an exit error event creates a new Modem IIIa2 message that the central station might need to add to their automation software Refer to Event 38 in the Modem IIIa2 Messages section of the Appendix in the ...

Страница 9: ... after event transmission displays CANCEL RPT SENT on the keypad The burglary alarm cancel window duration is the time programmed in the A Alarm Bell prompt Duress Passcode Prompts Duress Type A Duress Enable L Send Duress A new duress option is available that allows any passcode with the L Send Duress permission set to Yes to always send a Duress Alarm event upon entry This feature allows the con...

Страница 10: ...nd simplifies system operation Passcode Controlled Menus The system prompts a user to enter a passcode before viewing the keypad function list menu The system shows the user the menu options allowed according to the user s authority level Passcode controlled menus simplify system operation by providing a user with unique and pertinent options and information This feature is not intended for use on...

Страница 11: ...lable The default values for the Bright Dim mode are Bright 10 and Dim 3 On the D1260 and D1260B Keypads when the Sensor Reset command COMMAND 47 is executed Call for Service appears erroneously for a brief time on the display This effect also occurs when the control panel reboots Change the Service Passcode User ID 0 factory default value when the ANSI SIA CP 01 required Passcode Length parameter...

Страница 12: ...ccount are armed the keypads in those areas display the text programmed in the Area Acct Is On prompt The control panel is supposed to provide a way to alternately use the display text programmed in the Area is On prompt under the same conditions but this feature is not yet available When an invisible point is programmed with P RlyResp Type set to 2 Relay Latches the relay must be manually reset u...

Отзывы: