Release Notes for Version 7.07 

12/07

D7212GV2

Page 12 of 12

 

 

With a v7.06 or earlier D7212GV2 control panel, 
if a network interface module (NIM) is 
programmed as a Primary  Device in any Route 
Group, follow these programming rules: 

Assign Enhanced Communication Path 1 as 
the Primary Device in Route Group 1. 

Assign Enhanced Communication Path 2 as 
the Primary Device in Route Group 2. 

Assign Enhanced Communication Path 3 as 
the Primary Device in Route Group 3. 

Assign Enhanced Communication Path 4 as 
the Primary Device in Route Group 4. 

 

 

When all areas associated with an account are 
armed, the keypads in those areas display the text 
programmed in the 

Area # Acct Is On

 prompt. 

The control panel is supposed to provide a way to 
alternately use the display text programmed in the 

Area # is On

 prompt under the same conditions, 

but this feature is not yet available. 

 

When an invisible point is programmed with 

P# RlyResp Type

 set to 

2

 (Relay Latches), the 

relay must be manually reset using keypad 
[COMMAND 54]. Only visible points allow their 
associated relay to reset when the alarm memory 
is cleared with this setting. 

 

When the control panel is upgraded from V7.06 
and earlier to V7.07 and later, the 

AC Fail 

Display

 prompt defaults to 150 sec instead of to 

the intended factory default of 60 sec. 

 The 

Easy Exit

 feature was disabled in firmware 

version 7.07 to address

 the issues described in 

the 

GV2 Arming Without Passcode Technical Service 

Note

 (P/N: F01U077005). 

 

Содержание D7212GV2

Страница 1: ...07 RADXSKED v1 03 GV2AUX v1 01 Table 2 Supporting Literature for D7212GV2 with Version 7 07 Firmware and Later Document Name Part Number D7212GV2 Program Entry Guide F01U003804 03 D7212GV2 Program Record Sheet F01U003803 03 D7212GV2 Operation and Installation Guide F01U003805 02 D7212GV2 Approved Applications Compliance Guide F01U003806 02 Older revisions have alphabetic revision identifiers for e...

Страница 2: ...nt corrupted data account codes for systems that communicate with BIS 2 0 Security Engine These changes are only compatible with BIS Security Engine v2 1 1271 or later This addresses the issues described in the BIS SEE and GV2 G Series Technical Service Note P N F01U073249 Changes made allow the Relay Latches on point fault option for the P Relay Response Type feature to reset when a passcode is e...

Страница 3: ... is installed on the RPS workstation special software firewall settings might be required to allow outgoing traffic Refer to your firewall software for configuration information Any DX4020 or D9133TTL E used for enhanced communication to a central station receiver or with RPS over a network must be configured to use Datagram Mode 2 when the control panel firmware is version 7 06 and later Refer to...

Страница 4: ...evice are now included when a test report is sent using COMMAND 41 or a sked Corrections enhance the reliability and performance of RPS network connection These corrections also decrease the delay in reporting a break in the Ethernet connection to the control panel s Network Interface Module within the time limits required by UL For UL 1610 Line Security formerly Grade AA Intrusion System installa...

Страница 5: ... panel wide Communications Failure Relay output to activate when events in Route Groups 2 through 4 do not reach the central station Previously this relay output activated only on a communication failure for Route Group 1 2 5 Version 7 02 The Phone Line Supervision feature has improved accuracy in detecting the phone line The Modem IIIa2 product ID is changed to the same ID as the G Series control...

Страница 6: ...ion This feature was updated to manage the control panel clock adjustments over a period of time instead of simply jumping to the new time This enhancement allows consistent execution of Skeds at their intended times When a TimeSync adjustment is in process the Time Date idle text display is modified with a or sign to indicate control panel time is increasing or decreasing to match the target time...

Страница 7: ...ed Fire Bypass Trouble Annunciation The Fire Bypass warning display is modified to generate a Trouble warning tone that can be silenced with COMMAND 4 The trouble condition self clears when all bypassed fire points within the keypad s scope return to service This feature is always on and cannot be disabled Summary Fire Relay Options An option is added that changes the duration of the Panel Wide Su...

Страница 8: ...s the Entry Delay starts If the system is not disarmed within the programmed time an Exit Error Alarm is generated This feature is always enabled and has no configuration parameters The alarm with an exit error event creates a new Modem IIIa2 message that the central station might need to add to their automation software Refer to Event 38 in the Modem IIIa2 Messages section of the Appendix in the ...

Страница 9: ... after event transmission displays CANCEL RPT SENT on the keypad The burglary alarm cancel window duration is the time programmed in the A Alarm Bell prompt Duress Passcode Prompts Duress Type A Duress Enable L Send Duress A new duress option is available that allows any passcode with the L Send Duress permission set to Yes to always send a Duress Alarm event upon entry This feature allows the con...

Страница 10: ...nd simplifies system operation Passcode Controlled Menus The system prompts a user to enter a passcode before viewing the keypad function list menu The system shows the user the menu options allowed according to the user s authority level Passcode controlled menus simplify system operation by providing a user with unique and pertinent options and information This feature is not intended for use on...

Страница 11: ...lable The default values for the Bright Dim mode are Bright 10 and Dim 3 On the D1260 and D1260B Keypads when the Sensor Reset command COMMAND 47 is executed Call for Service appears erroneously for a brief time on the display This effect also occurs when the control panel reboots Change the Service Passcode User ID 0 factory default value when the ANSI SIA CP 01 required Passcode Length parameter...

Страница 12: ...ccount are armed the keypads in those areas display the text programmed in the Area Acct Is On prompt The control panel is supposed to provide a way to alternately use the display text programmed in the Area is On prompt under the same conditions but this feature is not yet available When an invisible point is programmed with P RlyResp Type set to 2 Relay Latches the relay must be manually reset u...

Отзывы: