30
|
Installation
AU/NZ
6 720 646 195a (2010/11)
4.5.4
Flue terminal plume re-direction
The flue discharge can be re-directed allowing some
plume redirection control, alternatively, a complete
plume management system can be fitted to the flue
terminal.
Re-directing the flue discharge
1. Remove screws (1) and rotate the terminal end (2)
through 180°.
1. Refit the terminal end (2) and secure with screws (1).
2. Loosen screws (3) and rotate the entire outlet
assembly to redirect the plume. Tighten screws (3) to
secure in the required position.
Fig. 40 Plume redirection
Fig. 41 Plume distance to opening
NOTE:
Do not rotate the complete terminal
assembly.
The flue terminal outlet has built-in stops to
limit rotation for horizontal fluing to allow
condensate to run back into the boiler for
safe disposal. Do not attempt to force
beyond the limit stops.
1
2
1.
3.
2.
3 1
±80°
180°
6720643895-34.1Wo
NOTE:
Outlet position
B
The flue terminal outlet position must
follow those stated in the relevant boiler
instruction manual.
When redirecting the flue discharge the
outlet terminal must be at least 1500mm
from any opening in the direction of the
discharge to prevent combustion
products from entering the building.
1
Opening in building
2
Flue discharge
3
Plume deflector
4
Minimum 1500mm from an opening in the
building
Tab. 21 Key to figure 41
6720643895-119.1Wo
1
3
4
2