Central Processing Unit
5–21
1070 072 145-102 (01.07) GB
Pin assignment, female DB-25 connector (active):
Pin
Signal designation
Signal function
Housing
Screen
Screening
10
12 V out
12 V out
9
12 V in
12 V in
21
12 V GND
12 V reference conductor
12
RXD+
Receive data +
24
RXD–
Receive data –
13
TXD+
Transmit data +
25
TXD–
Transmit data –
Connecting cable
.
Do not route data lines parallel to power lines.
A premanufactured connecting cable is available to connect to the X31 inter-
face connector:
Designation
Order no.
K16 Connecting cable, 5 m
1070 054 956
The maximum permissible length, even of premanufactured cables, de-
pends on the type of cable used. The cable shall be a screened,
twisted-con-
ductor 14 x 0.14 mm
2
cable. The following values may not be exceeded:
D
Line resistance
0,135
W
/m
D
Line capacitance
120 pF/m
Interface
Baud rate [Baud]
max. Cable length [m]
V.24
up to 57600
15
20 mA
9600
300
19200
150
38400
100
57600
50
Содержание CL200
Страница 3: ...Antriebs und Steuerungstechnik CL200 Manual CL200 102 Edition ...
Страница 8: ...Contents VIII 1070 072 145 102 01 07 GB Notes ...
Страница 24: ...System Introduction 2 8 1070 072 145 102 01 07 GB Notes ...
Страница 38: ...Module Racks 3 14 1070 072 145 102 01 07 GB Notes ...
Страница 82: ...E 24 V Digital Input Modules 6 6 1070 072 145 102 01 07 GB Notes ...
Страница 104: ...Digital Input Output Modules 8 10 1070 072 145 102 01 07 GB Notes ...
Страница 110: ...DP EA4 Peripheral Bus Station Module 9 6 1070 072 145 102 01 07 GB Notizen ...
Страница 114: ...AG S Expansion Module 10 4 1070 072 145 102 01 07 GB Notizen ...
Страница 122: ...R200 R200P COM2 E Communication Modules 11 8 1070 072 145 102 01 07 GB Notizen ...
Страница 158: ...Appendix A 4 1070 072 145 102 01 07 GB Notes ...