Central Processing Unit
5–11
1070 072 145-102 (01.07) GB
5.4.2
X71 Interrupt and High-speed Counter Inputs
.
Refer also to “CL200 Operations List”, order no. in section 1.6.
The interrupt inputs and high-speed counters are connected via the female
DB-9 connector of the X71 interface.
Pin assignment:
Pin no.
Signal
designation
Signal function
Signal
direction
1
II0
Interrupt input 0
²
2
GND
Ground
3
II1
Interrupt input 1
²
4
GND
Ground
5
II2
Interrupt input 2
²
6
OCI0
Counter input 0
²
7
OCD0
Counter direction 0
²
8
OCI1
Counter input 1
²
9
OCD1
Counter direction 1
²
Housing
Screen
Interrupt and counter inputs are characterized by very short delay intervals.
Inputs are not electrically isolated. They are protected against polarity rever-
sal to a
$
max. 30 V potential.
Inputs do not feature visual indicators.
Input signal interpretation occurs dynamically.
Inputs can be connected to an output of the A 24 V– / 0.5 A output module
without a load.
Содержание CL200
Страница 3: ...Antriebs und Steuerungstechnik CL200 Manual CL200 102 Edition ...
Страница 8: ...Contents VIII 1070 072 145 102 01 07 GB Notes ...
Страница 24: ...System Introduction 2 8 1070 072 145 102 01 07 GB Notes ...
Страница 38: ...Module Racks 3 14 1070 072 145 102 01 07 GB Notes ...
Страница 82: ...E 24 V Digital Input Modules 6 6 1070 072 145 102 01 07 GB Notes ...
Страница 104: ...Digital Input Output Modules 8 10 1070 072 145 102 01 07 GB Notes ...
Страница 110: ...DP EA4 Peripheral Bus Station Module 9 6 1070 072 145 102 01 07 GB Notizen ...
Страница 114: ...AG S Expansion Module 10 4 1070 072 145 102 01 07 GB Notizen ...
Страница 122: ...R200 R200P COM2 E Communication Modules 11 8 1070 072 145 102 01 07 GB Notizen ...
Страница 158: ...Appendix A 4 1070 072 145 102 01 07 GB Notes ...