24
en | Installation
AVIOTEC IP starlight 8000
2020.08 | 01 | F.01U.391.015
Operation and Commissioning Manual
Bosch Sicherheitssysteme GmbH
Alarm out
Use the alarm output for switching external devices such as lamps or sirens.
Alarm output switching capability:
–
Max. voltage 30 VAC or +40 VDC. Max. 0.5 A continuous, 10 VA.
Pin
Alarm socket
3
Alarm out
6
The maximum wire diameter is 18-28 AWG, UL 16-28 AWG for both stranded and solid; cut
back 7 mm (0.28 in) of insulation.
4.9
Alarm input
The alarm contact assignment is shown in the figure below: