AUTODOME inteox 7000i ‑ 2MP (pendant)

en

Installation Manual (pendant)

Содержание AUTODOME inteox 7000i 2MP

Страница 1: ...AUTODOME inteox 7000i 2MP pendant en Installation Manual pendant ...

Страница 2: ......

Страница 3: ...oute Power through Intermediate Power Supply Box 27 9 4 Attach Pendant Arm to Power Supply Box 30 9 5 Make Connections in the Power Supply Box 31 9 6 Installing the VGA PEND WPLATE 32 9 7 Attach Pendant to Arm and Tighten 35 10 Installing the Roof Parapet and Pipe Mounts 37 10 1 Description 37 10 2 Route Wires and Attach Connectors 37 10 3 Attach Cover Door to Power Supply Box 42 10 4 Installing t...

Страница 4: ... and the product described 1 2 Legal Information Copyright This manual is the intellectual property of Bosch Security Systems and is protected by copyright All rights reserved Trademarks All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly 1 3 Safety Precautions Danger Indicates a hazardous situation which if not avoid...

Страница 5: ...er adjustment of other controls may cause damage to the unit Use of controls or adjustments or performance of procedures other than those specified may result in hazardous radiation exposure 7 Overloading Do not overload outlets and extension cords This can cause fire or electrical shock 8 Power cord and plug protection Protect the plug and power cord from foot traffic being pinched by items place...

Страница 6: ...as been dropped or the unit cabinet is damaged unit exhibits a distinct change in performance unit does not operate normally when the user correctly follows the operating instructions 13 Replacement parts Be sure the service technician uses replacement parts specified by the manufacturer or that have the same characteristics as the original parts Unauthorized substitutions may cause fire electrica...

Страница 7: ...CORPORATED Warning ROUTING OF EXTERNAL WIRING MUST BE DONE THROUGH A PERMANENTLY EARTHED METAL CONDUIT Warning THE CAMERA MUST BE MOUNTED DIRECTLY AND PERMANENTLY TO A NON COMBUSTIBLE SURFACE Notice Always use a shielded twisted pair STP connection cable and a shielded RJ45 network cable connector where the camera is used outdoors or the network cable is routed outdoors Always use shielded cables ...

Страница 8: ...only after this unit has had its ground terminal connected properly to a ground source Disconnect the unit s input connectors from outdoor equipment before disconnecting the grounding terminal Follow proper safety precautions such as grounding for any outdoor device connected to this unit U S A models only Section 810 of the National Electrical Code ANSI NFPA No 70 provides information regarding p...

Страница 9: ...l This device has no user serviceable parts Notice This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Notice Ce produit est un appareil de Classe A Son utilisation dans une zone résidentielle risque de provoquer des interférences Le cas échéant l utilisateur devra prendre les mesures nécessa...

Страница 10: ...esigned to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and radiates radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful i...

Страница 11: ...6 1329 Email repair us bosch com Customer Service Telephone 800 289 0096 option 3 Fax 800 315 0470 Email orders us bosch com Technical Support Telephone 800 289 0096 option 4 Fax 800 315 0470 Email technical support us bosch com Europe Middle East Africa and Asia Pacific Regions Please contact your local distributor or Bosch sales office Use this link https www boschsecurity com corporate where to...

Страница 12: ... Please contact Bosch Security Systems in the event of damaged goods The original packing carton if undamaged is the safest container in which to transport the unit and must be used if returning the unit for service Save it for possible future use 2 1 Parts List Quantity Component 1 AUTODOME inteox 7000i pendant camera 2 2 Tools Required The following table lists additional products sold separatel...

Страница 13: ...can cause the operating temperature of the camera to go above the maximum If you install a camera in an enclosed area make sure that the operating temperature of the camera does not go above the maximum temperature The maximum operating temperature is 40 C 104 F for in ceiling models 55 C 131 F for pendant models Make sure that air circulates around the camera to supply cooling The following table...

Страница 14: ...g Power Supply Boxes VGA ROOF MOUNT Power Supply Box and cover with 120 VAC transformer or with 230 VAC transformer VG4 A PSU1 VG4 A PSU2 Pipe Mount with one of the following Power Supply Boxes VG4 A 9543 Power Supply Box and cover with 120 VAC transformer or with 230 VAC transformer VG4 A PSU1 VG4 A PSU2 The following table lists the optional parts sold separately that you may need for attaching ...

Страница 15: ...PLATE page 32 Warning For units intended to be installed outdoors All wiring power and I O cabling connecting to the unit must be routed separately inside different permanently earthed metal conduits not supplied Warning To minimize the potential for corrosion on the housing use only Bosch hardware and mounts See number 5 Installation in a corrosive environment in the section Recommended Use of Yo...

Страница 16: ...o stabilize the AUTODOME against strong winds Use the LTC 9230 01 Flat Roof Mount Adapter where appropriate This adapter is made specifically for AUTODOME roof applications Extreme Mount Applications Unique camera mounting applications that are impacted by extreme high winds heavy traffic or other conditions may require additional measures to stabilize the camera Contact a manufacturer that specia...

Страница 17: ...ions when the camera zooms in on a target Use the pendant arm mount if possible This mount option provides the most stability for the camera Use guy wires to protect against strong winds if using the parapet mount Field of View Select a location and viewing angle that allows the flow of people to move across the camera s field of view Avoid motion that moves directly towards the camera Avoid locat...

Страница 18: ... removed from the housing for no more than five 5 minutes Remove the bubble from a pendant housing 1 Using both hands apply a firm counterclockwise looking up at the dome rotational force on the pendant bubble assembly to set the bubble latch 2 Insert a small 2 mm straight blade screw driver into the release opening in the bubble trim ring to release the lock and then remove the screwdriver 4 Firm...

Страница 19: ... card is optional Note Disconnect power to the camera while adding or removing an SD card 1 Follow the steps in one of these sections depending on the type of camera mount Remove bubble from in ceiling housing or Remove bubble from pendant housing 2 Slide the SD card into the slot Press down the end of the SD cards until you hear a click and the card locks into place 3 Follow the steps in one of t...

Страница 20: ...nstallation Manual pendant Bosch Security Systems 7 Replacing the trim ring and bubble Replace the bubble in a pendant housing 1 Insert the bubble and trim ring assembly into the pendant housing 2 Rotate the assembly clockwise until it locks The latch mechanism makes a click when it locks ...

Страница 21: ...kg 265 lb pull out force is recommended The mounting material must be able to withstand this pull out force For example 19 mm 3 4 inch minimum for plywood 3 Secure the Power Supply Box to the mounting surface For a Wall installation Use four 4 corrosion resistant stainless steel studs not supplied Then proceed to Step 5 below For a Corner installation Secure the Corner Plate to the wall corner usi...

Страница 22: ...7000i 2MP pendant 2020 07 1 0 Installation Manual pendant Bosch Security Systems Warning For units intended to be installed outdoors All wiring power and I O cabling connecting to the unit must be routed separately inside different permanently earthed metal conduits not supplied ...

Страница 23: ... A readily accessible 2 pole disconnect device with a contact separation of at least 3 mm 0 12 in must be incorporated Making the Connections Notice Refer to the Connection page 52 chapter for wire specifications and distances 1 Route all video control and alarm wires through the earth grounded conduit fitting on the right side of the power box 2 Route the high voltage 115 230 VAC lines through th...

Страница 24: ...lay Connector P104 Pin Description Pin Description Pin Description 1 Alarm Out 1 1 Alarm in 3 1 Alarm Out 4 Normally Open 2 Alarm Out 2 2 Alarm in 4 2 Alarm Out 4 COM 3 Alarm Out 3 3 Alarm in 5 3 Alarm Out 4 Normally Closed 4 Alarm Ground 4 Alarm in 6 4 Earth Ground 5 Alarm in 7 5 Analog Alarm 1 6 Alarm Ground 6 Analog Alarm 2 7 Ground For in ceiling mount only Low Voltage TTL 3 3V can also be use...

Страница 25: ...LINE NC NEUT Figure 9 2 Pendant arm power supply box 1 Ground Screw 7 P101 Connector Power In 120 VAC 220 VAC 2 From Harness Nexus cable bundle 8 P106 Connector Control In Out for external audio input and output 3 In Out 1 2 in 15 mm NPS Fitting 9 P105 Connector Audio to camera 4 Ethernet connector 10 Power In 3 4 in 20 mm NPS Fitting 5 P107 Connector 24 VAC to camera 11 Audio Input Output 3 4 in ...

Страница 26: ...s No Connector Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Ground Grounding Screw P101 115 230 VAC or 24 VAC Power In Line NC Neutral P106 SERIAL COMMUNICATIONS CODE Audio IN Audio in signal ground CODE Audio IN Earth GND Ground Audio RXD Audio OUT TXD Audio OUT Audio out signal ground Signal GND Ground P107 24 VAC Power Arm Harness Camera 24 VAC Camera 24 VAC Earth Ground Heater 24 VAC Heater 24 VAC Tabl...

Страница 27: ...illustration below depicts A VG4 PSU1 VG4 PSU2 Power Supply Box The main power supply connected to the P101 connector and to the grounding screw The 24 VAC power out wire connected to the P107 heater power connectors GND TXD RXD C C GND TXD RXD C C P101 1 2 3 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 ...

Страница 28: ... trim the high voltage 120 230 VAC power and ground wires with sufficient slack to reach their connector terminal in the box but not so long as to be pinched by or to obstruct closing the cover door 3 Attach the supplied 3 pin power plug to the incoming high voltage power wires in the box Refer to connector P101 in the table above and to the image below for an illustration of these connections P10...

Страница 29: ...connector terminal in the box but not so long as to be pinched by or to obstruct closing the cover door 8 Attach the supplied 3 pin power plug to the incoming 24 VAC power wires in the box as illustrated below GND TXD RXD C C GND TXD RXD C C P101 1 2 3 6 5 4 3 2 1 6 5 4 5 4 3 2 1 6 5 4 5 4 5 4 6 5 4 5 4 6 5 4 5 4 5 4 6 5 4 6 5 4 6 5 4 3 2 1 3 2 1 6 5 4 3 2 5 4 3 2 3 2 5 4 3 2 P106 P105 P107 XF102 ...

Страница 30: ...hing its pin lever up and holding it Notice Both Hinge Pins must be fully compressed to open unlock the hinges of the Pendant Arm and before proceeding to the next step 3 While continuing to hold the top hinge pin open and align the top and bottom hinges of the Pendant Arm to their mating points on the Power Supply Box See the illustration above 4 Once you have aligned the hinges release the top h...

Страница 31: ...m inputs and relay outputs connect the 4 pin Alarms Out the 6 pin Alarms In and the 7 pin Relay connectors from the Pendant Connector Harness to their mating connectors installed previously to the incoming alarm wires 6 Connect the 3 pin Power In Plug installed previously to its mating connector P101 on the left side of the box 7 Connect the incoming RJ45 video connector installed previously to it...

Страница 32: ...ncluded Secure the Mounting Plate to the Corner Plate using the four 4 3 8 x 1 3 4 inch bolts and split lock washers supplied 2 For a Mast or pole installation The metal straps included with the Mast mount accommodate a pole with a diameter of 100 380 mm 4 15 in You must use a banding tool sold separately for a mast or pole installation In addition you must obtain a 3 4 in 20 mm right angle condui...

Страница 33: ...pin lever up and holding it Note Both Hinge Pins must be fully compressed to open unlock the hinges of the Pendant Arm and before proceeding to the next step 3 While continuing to hold the top hinge pin open align the top and bottom hinges of the Pendant Arm to their mating points on the Mounting Plate 4 Once you have the hinges aligned release the top hinge pin to engage its mating hinge on the M...

Страница 34: ...and distances 1 Route all incoming wires through one of the earth grounded conduits at the bottom of the Mounting Plate For a mast mount route all wires through the right angle conduit 2 Attach the water tight plug to the other conduit 3 Attach the grounding spade terminal item 1 below to one of the spade terminals inside the Mounting Plate Figure 9 11 Mounting Plate Inside Detail Ref Description ...

Страница 35: ...cable 7 13 Connect the incoming serial communication wires to the 6 pin mating connector supplied with the VGA PEND WPLATE kit Refer to the Power Supply Box Connections table above for details 14 Attach the 6 pin serial communication mating connector to the Serial Communications cable cable 8 15 Connect the Earth ground wire if available to the crimp ring terminal inside the Mounting Plate Note Th...

Страница 36: ...ome housing hook on the Pendant Arm hinge pin allowing the dome to rotate around the pin 3 Rotate the dome housing down to a vertical position and gently push upward to engage the connector on top of the dome housing Caution If you feel any resistance when rotating the dome housing or when engaging the connector stop immediately and start over 4 Hold the Pendant housing in position while tightenin...

Страница 37: ... to maintain the integrity of a Type 4X environment the connected equipment must have a Type 4X environmental rating In order to maintain the integrity of a Type 4 environment the connected equipment must have a Type 4 Type 4X Type 6 or Type 6P environmental rating 10 2 Route Wires and Attach Connectors Power wires must be routed to the left front side of the Power Supply Box through a separate el...

Страница 38: ...ire Used for Audio input and output in AUTODOME 7000 Series 2 P101 Connector 7 24 VAC Power Out 3 Ground Connection 8 P107 Connector 4 Transformer 9 Earth grounded conduit with power input and earth ground connection 5 Ethernet Wire 10 Earth grounded conduit with Ethernet video control audio input and output to head end system 11 Earth grounded conduit to camera Wiring the Power Supply Box Notice ...

Страница 39: ... the camera will be mounted Attach the supplied 5 pin 24 VAC Dome plug to the wire ends inside the box Refer to connector P107 in the Power Supply Box Connections section below Wiring the Fiber Optic Model If installing a Fiber Optic model follow these steps Notice Refer to the Connection page 52 chapter for fiber optic specifications For instructions on installing a fiber optic module into a powe...

Страница 40: ...on Manual pendant Bosch Security Systems GND TXD RXD C C P101 P106 XF102 XF103 XF101 5 4 3 2 1 J103 J103 J103 J102 J101 LED HTR DOME 24V NC 24V FUSE FUSE FUSE FUSE Figure 10 2 Fiber Optic Ethernet Module installed 1 RJ45 Ethernet socket 2 Port for SFP module sold separately 3 Fiber Optic cable user supplied ...

Страница 41: ...1 J101 J101 J101 J101 J101 J101 J101 LED 6 5 4 3 2 1 GND GND GND TXD RXD C C XD XD XD XD HTR DOME FUSE FUSE FUSE FUSE FUSE FUSE FUSE FUSE FUSE FUSE FUSE FUSE FUSE FUSE FUSE FUSE FUSE FUSE FUSE FUSE LINE NC NEUT Figure 10 3 Power Supply Box Connections 1 Ground Screw 5 Power In 2 Transformer 115 230 VAC Modes 6 In Out 1 2 in 15 mm NPS Fitting 3 In Out to camera 7 Power In 3 4 in 20 mm NPS Fitting 4...

Страница 42: ...g the door GND TXD RXD C C GND TXD RXD C C FUSE FUSE FUSE 90 o HTR DOME LINE NC NEUT Figure 10 4 Align Cover Door Hinge to Power Box 1 Power Supply Box 5 Hold Hinge Pin Open 2 Cover Door 6 Open Position 3 Align Top Hinge 7 Hinge Pin Stop 4 Align Bottom Hinge 2 Open the top hinge by pushing its pin lever outward and holding it open Note Both Hinge Pins must be fully compressed to open unlock the fe...

Страница 43: ... shall be tightened securely 5 in 12 7 cm min Figure 10 5 Pipe Mount 1 Gasket 2 Flange 3 Cap 1 Before installing the Top Mounting Flange ensure there is an adequate opening in the ceiling or mounting structure for the wires to pass through 2 Secure the pipe Flange with supplied gasket to the ceiling or other supporting structure using four 4 10 mm 3 8 inch diameter fasteners Notice Each fastener m...

Страница 44: ...e Cap onto the down pipe and tighten securely to prevent leaks Warning You must thread the Dome Cap onto the pipe until it is tight Failure to do so can result in damage or serious injury or death 10 5 Wire the Pipe Interface Board This section provides instructions for connecting wires and cables to the Pipe Interface Board as illustrated below Refer to the Connection page 52 chapter for cable an...

Страница 45: ...nput in an AUTODOME 7000 Series camera remove this resistor P105 6 Data In Out P105 AWG 26 16 1 Biphase C For AUTODOME 7000 Series AUDIO IN Audio in signal ground 2 Biphase C For AUTODOME 7000 Series AUDIO IN 3 Earth Ground 4 RxD For AUTODOME 7000 Series AUDIO OUT 5 TxD For AUTODOME 7000 Series AUDIO OUT Audio out signal ground 6 Signal Ground 7 Alarms In EOLR Supervised 1 2 P104 AWG 26 16 7 Groun...

Страница 46: ...eir respective terminals on the P105 connector on the Pipe Interface Board 3 Connect the 24 VAC power wires to the P101 connector on the Pipe Interface Board If this model has a heater connect the 24 VAC heater power wires to connector P107 Caution To protect the camera from damage due to cold temperatures ensure that you connect the 24 VAC heater power wires to the P101 connector Connecting Alarm...

Страница 47: ...Ground For in ceiling mount only Low Voltage TTL 3 3V can also be used 4 Connect the plugs to their mating connectors P103 and P102 on the Pipe Interface Board 1 To connect supervised alarms and relays attach the appropriate wires to their terminals on the P104 connector on the Pipe Interface Board see above 2 Insert the Pipe Interface Board into the down pipe and fasten the three 3 retaining scre...

Страница 48: ...drop 2a Dome Cap 2b Recessed Hinge Pin 2c Dome Connector 3 Rotate down to engage dome connector 4 Tighten the two 2 mounting screws to a minimum torque of 10 12 N m 90 105 in lbs 3 Drop the Pendant down slightly to engage the dome hook and hinge pin of the Dome Cap allowing the dome to rotate around the hinge pin 4 Rotate the dome housing down to a vertical position and gently push upward to engag...

Страница 49: ...lling a Parapet Roof Mount 7 Tighten the three 3 10 mm 3 8 inch stainless steel hex bolts on the bracket to lock the Parapet Arm in position Caution Do not over tighten the bolts The maximum torque is 34 N m 25 ft lb 10 7 Make Connections in the Power Supply Box 1 Attach the earth ground wire to the grounding screw on the left side of the box 2 Connect the 24 VAC to Dome plug installed previously ...

Страница 50: ...000i 2MP pendant 2020 07 1 0 Installation Manual pendant Bosch Security Systems 11 Finalizing installation Remove the plastic on the bubble After you complete all other installation steps remove the plastic material that is protection for the bubble ...

Страница 51: ...e the bubble counterclockwise approximately 20 degrees until the bubble assembly releases from the pendant housing 4 Locate the four tabs item 1 below inside the trim ring that attach the trim ring to the bubble 5 Gently push each tab out and down away from the bubble to disengage the tabs 6 Remove the bubble from the trim ring 7 Insert the replacement bubble inside the trim ring and align the rel...

Страница 52: ...low 1 2 3 4 1 2 2 4 Figure 13 1 AUTODOME 7000 Series System Configuration 1 AUTODOME 7000 Series 2 IP Connection 3 Network Switch 4 Computer Notice You can also use the Bosch Video Client software application to configure the network settings for an AUTODOME 7000 Series camera Go to www boschsecurity com to download the Configuration Manager software and Operating Manual 13 2 Power Cable and Wire ...

Страница 53: ...compliant with the IEEE 802 3at class 4 standard The camera can be connected simultaneously to a 24 VAC power supply and to a High PoE 60 W midspan The camera uses power from the 24 VAC power supply If this power supply fails the camera seamlessly switches power input to the High PoE 60 W midspan The camera switches back to the 24 VAC power supply once power is restored Refer to Using the IP Inter...

Страница 54: ...bundling requirements and limitations 13 4 Fiber Optic Ethernet Media Converter Optional The fiber optic media converter is designed to transmit 10 100 Mbps Ethernet signals over fiber optic cable using 10 100 Mbps Small Form factor Pluggable SFP modules The SFP modules are available as multi mode fiber MMF or single mode fiber SMF models with a single SC connector or dual fiber with an LC connect...

Страница 55: ...g on how the alarm is configured a short or a break in the alarm s circuit can trigger the tamper signal Configuring Supervised Alarms inputs 1 and 2 To configure Alarm 1 or 2 pin 5 or 6 for supervision you must install a 2 2 K end of line resistor in the circuit Then you program the alarms through Configuration to either Normally Open N O or Normally Closed N C Notice Only Alarms 1 and 2 pins 5 o...

Страница 56: ...ome Connector 2 Alarm 1 or 2 only Pin 5 or 6 4 Ground Pin 7 3 From Configuration select Interfaces Alarm Inputs select the number of the Alarm input and finally select N C See the table below for contact and condition details AUTODOME Programmed N C S Contact Alarm Condition Open Alarm Closed Normal Short Tamper Configuring Non supervised Alarms inputs 3 through 7 You can configure alarms 3 throug...

Страница 57: ...C See the table below for contact and condition details AUTODOME Programmed N C Circuit Alarm Indication Open Alarm Closed Normal Alarm Outputs The camera incorporates two 2 types of alarm outputs one dry contact relay and three 3 open collector outputs or transistor outputs Configuring a Dry Contact Relay The dry contact relay acts like an on off switch It has a maximum voltage rating of 2 A 30 D...

Страница 58: ...s should be complied with in all cases Max Input Voltage 1 Vrms Impedance 9 K Ω typical Shield Bare copper braid 95 coverage Internal gain level adjustment is available in case the signal level is too low Audio Line Output Specifications The following Line Output specifications should be complied with in all cases Typical Output Voltage 1 Vrms Impedance 1 5 K Ω typical Shield Bare copper braid 95 ...

Страница 59: ...t to the Audio_Out RXD output terminal 2 Connect the audio line level output signal ground to the Audio_Out TXD output terminal Figure 13 6 Connections for audio over an Ethernet network 1 Audio_In C 7 AUTODOME Data In Out 2 Audio_In C 8 P105 P106 Connector 3 Earth Ground 9 Audio Out 4 Audio_Out RXD 5 Audio_Out TXD 6 Signal Ground Notice Separate the audio cables from the AC power lines to avoid n...

Страница 60: ...eojet Generic 4 Reboot the unit using one of the following methods In the web browser type the IP address and then reset without any punctuation Press the Enter key OR In Configuration Manager right click the IP address and click Restart 4 Wait two minutes for the process to complete If you cannot control the unit after the firmware upgrade then cycle the power to the unit If a power reset does no...

Страница 61: ...USA Telephone 800 366 2283 Fax 800 366 1329 Email cctv repair us bosch com Customer Service Telephone 888 289 0096 Fax 585 223 9180 Email security sales us bosch com Technical Support Telephone 800 326 1450 Fax 717 735 6560 Email technical support us bosch com Canada Telephone 514 738 2434 Fax 514 738 8480 Europe Middle East Africa and Asia Pacific Regions Please contact your local distributor or ...

Страница 62: ...se clean dry compressed air preferably from a spray can to remove any dust from the interior surface Warning Do not use alcohol based solutions to clean the polycarbonate bubble This will cause the polycarbonate to cloud and over time cause stress aging which makes the bubble brittle Cleaning the Bubble Exterior The exterior of the polycarbonate bubble is hard coated for extra protection If cleani...

Страница 63: ...en support Bosch Security and Safety Systems offers support in these areas Apps Tools Building Information Modeling Commissioning Warranty Troubleshooting Repair Exchange Product Security Bosch Building Technologies Academy Visit the Bosch Building Technologies Academy website and have access to training courses video tutorials and documents https www boschsecurity com xc en support training ...

Страница 64: ...64 Support AUTODOME inteox 7000i 2MP pendant 2020 07 1 0 Installation Manual pendant Bosch Security Systems ...