6.2.2
Viewing customer service program
Customer Service Program
Step
Displayed
step
Action
Can advance
step
Time
Temperature
Water
amount
Remarks
0
0
Check Coil
no
--
Checks pumps and other components
(when switched on)
1
0
Drain Pump
15s
Drain pump O
K
2
1,2
Filling
partly
72s
3.0 L
Checks if water level above filter level
3
3,4
Pause
yes
10s
Checks water level
4
5,6,10,11 Drain Pump
yes
20s
empty Sump base completely empty
5
12,13,14 F Main Pump
no
96s
4.0 L
Checks if water level at top of coarse filter -
main pump starts at displayed step 13
6
15
Main Pump + Soap
Dispenser
yes
10s
7
16
Main Pump + Aqua
Sensor Calibration
partly
110s
8
17
Main Pump + Heating
104°F
9
18
Pause
yes
5s
10
19
Main Pump
yes
5s
Start main pump
11
20
Main Pump + Rinse
Agent + Heating
yes
60s
# of dispenser coil impulses = rinse agent
setting
12
21
Main Pump + Heating
yes
149° F
About 2.5°F/min
13
22
Main Pump
yes
15s
14
24
Drain Pump
no
--
Displays "0" when done
Hint: If a failure occurs the program goes on, stops or ends according to the failure handling.
Remark: Filling can not be stepped over