AMAX panel 2000 / AMAX panel 2000 EN
Programming sheets | en
85
Bosch Sicherheitssysteme GmbH
Installation Manual
F.01U.241.127 | V4 | 2011.12
10.5
Output Programming
10.5.1
Keypad Buzzer
10.5.2
Warning Device 1 / OC1 Output
10.5.3
Warning Device 2 / OC2 Output
10.5.4
Optional Relay Output / OC3
10.5.5
DX3010 Output
7
24-Hour
8
Tamper
9
Fire
10
External Fault
11
Bolt Contact
12
Key Switch Toggle
13
Key Switch on/off
Zone Type
Description
Location 370 Location Default
Keypad beeps when siren on 1=Disable, 1=Enable
370
0
Output 1
Location Default
Event type (fixed value)
3
EN
Polarity Mode (0=Steady, 1=Pulse)
371
0
EN=0
Output Duration (001-999sec/000=on)
372-374
000
EN=180
NOTICE!
When the triggered zone is programmed as silent zone, keypad output and OC1 output do not
response. Other outputs are as normal.
Output 2
Location Default
Event type (Refer to output events option)
375
3
EN=3
Polarity Mode (0=Steady, 1=Pulse)
376
0
EN=0
Output Duration (001-999sec/000=on)
377-379
000
EN=180
Optional Relay Output
Event Type (Refer to output events option)
380
0
Polarity Mode (0=Steady, 1=Pulse)
381
0
Output Duration (001-999sec/000=on)
382-384
030
Location Location Default
Relay Output 1
Event Type (Refer to output events option)
385
0