AMAX panel 2000 / AMAX panel 2000 EN
System Informations 2 | en
71
Bosch Sicherheitssysteme GmbH
Installation Manual
F.01U.241.127 | V4 | 2011.12
1.
Only after a Dynamic Battery Test report that the backup battery voltage is normal and
fault is reset.
2.
When the output programmed duration is up.
If this duration is programmed as 000, the output will continue till the AC MAINS power is
restored.
8 – RF Power Fault
This output operates when RF power is lost.
The output is reset:
1.
When the output programmed duration is up.
2.
lf this duration is programmed as 000, the output will continue till the RF power is
Restored and the fault is reset.
If this duration is programmed as 000, the output will continue till the AC MAINS power is
restored.
9 – Tamper
This output operates when a Tamper condition occurs.
The output is reset:
1.
When the output programmed duration is up.
lf this duration is programmed as 000, the output will continue till the Tamper condition is
Restored and Tamper is reset.
10 – External Fault
This output operates when an External Fault occurs.
The output is reset:
1.
When the output programmed duration is up.
lf this duration is programmed as 000, the output will continue till the External Fault is
Restored and the fault is reset.
11 – All Faults
This output operates when a Fault occurs.
The output is reset:
1.
When the output programmed duration is up.
lf this duration is programmed as 000, the output will continue till the Fault is Restored and
the fault is reset.
12 – AWAY Armed
This output operates when System is AWAY Armed.
The output is reset:
1.
When the output programmed duration is up.
lf this duration is programmed as 000, the output will continue till the System is Disarmed.
13 – STAY Armed
This output operates when System is STAY Armed.
The output is reset:
1.
When the output programmed duration is up.
lf this duration is programmed as 000, the output will continue till the System is Disarmed.
14 – 24h Alarm
This output operates when a 24h alarm occurs.
The output is reset:
1.
When the system is reseted
When the output programmed duration is up