en | System Informations 2
AMAX panel 2000 / AMAX panel 2000 EN
F.01U.241.127 | V4 | 2011.12
Installation Manual
Bosch Sicherheitssysteme GmbH
The output is reset:
1.
When the system is disarmed
2.
When the output programmed duration is up.
If this duration is programmed as 000, the output will continue till the system disarmed.
3 – System Alarm
This output operates when an alarm occurs.
The output is reset:
1.
When the system is disarmed and alarm is reset.
2.
When the output programmed duration is up.
When a new alarm occurred, the alarm will reset the alarm time.
If this duration is programmed as 000, the output will continue till the zone restore or system
disarmed.
4 – Entry/Exit Delay Warning
Entry Delay Warning
This output operates during Entry Time.
The output is reset:
1.
When the system disarmed
2.
When Entry Time expires
3.
When the output programmed duration is up.
Exit Delay Warning
This output operates during Exit Time when the control panel is armed.
The output is reset:
1.
When the system is disarmed
2.
When Exit Time expires
3.
When the output programmed duration is up.
If this duration is programmed as 000, the output will continue till the delay warning duration
is up.
5 – Telephone Line Fail
This output operates when a telephone line fault occurs.
The output is reset:
1.
When the Telephone line is restored and fault is reset.
2.
When the output programmed duration is up.
If this duration is programmed as 000, the output will continue till the telephone line is
restored.
6 – AC MAINS Fail
This output operates when a AC MAINS fault occurs.
The output is reset:
1.
When the AC power supply is restored
2.
When the output programmed duration is up.
If this duration is programmed as 000, the output will continue till the AC MAINS power is
restored.
7 – Low Battery
This output operates when a Low Battery fault occurs.
The Dynamic Battery Test is performed every 4 hours after the system is powered up and
every time the system is armed.
The output is reset:
Содержание AMAX panel 2000 EN ICP-AMAX-P-EN
Страница 1: ...AMAX panel 2000 AMAX panel 2000 EN ICP AMAX P ICP AMAX P EN en Installation Manual ...
Страница 2: ......
Страница 4: ...4 ICP AMAX P ICP AMAX P EN F 01U 241 127 V4 2011 12 Bosch Sicherheitssysteme GmbH ...
Страница 91: ......